SBIR/STTR Research Award

Head mounted display apparatus for visual field test

Award identifier 8315dbb403f0bc37d044037ffa9f8f4b07e6db3259d4e763fa18151acac36ce3Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$856,257

Program and phase

SBIR · Phase II

Award year

2008

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
BIOFORMATIX, INC.
Proposal award date
Not reported
Contract end date
Not reported
UEI
Not reported
Solicitation number
PHS2007-2
Topic code
Not reported

Research abstract

DESCRIPTION (provided by applicant): The goal of this Phase II SBIR project is to design, develop, test and demonstrate clinical use of a lightweight, low cost, head mounted perimeter (apparatus for visual field test). The HMDField device integrates commer cial off-the-shelf hardware components (high performance head mounted display and eye tracker), and an interactive computer program for data collection. The software is designed for a personal computer and permits implementation of a variety of testing str ategies and test stimuli. The apparatus allows the patient an unprecedented freedom of movement of the head and body, thus minimizing or even eliminating the stress and fatigue common with the conventional visual field testing systems. Eye tracker enables real-time monitoring of fixation (gaze direction). In the novel visual grasp mode, it is used to capture responses to the light stimuli, thus providing hands-free and highly intuitive mode of operation that relies on the visual grasp reflex. Following succ essful Phase I feasibility demonstration, Phase II effort will concentrate on development of a fully functional production prototype of the HMDField apparatus, including hardware and software integration, and on clinical tests of its utility in diagnosis o f glaucoma. Acceptance of this novel device by patients and clinicians will also be evaluated. PUBLIC HEALTH RELEVANCE: The visual field test is one of the basic diagnostic tools of ophthalmology and optometry and is especially useful in the detection of g laucoma. The visual field test, if easily administered, would also have great use in neurosurgery and general medicine. The HMDField device proposed here is a major step in simplifying the test procedure and in making it more user-friendly. Low weight, fre edom of movement and hands-free operation are of particular importance for the elderly and for disabled and/or immobilized patients.

Technology keywords

Not reported

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.