Research abstract
Acrolein (CH2=CHCHO) has been identified by the U.S. Clean Air Act as a hazardous air pollutant because of its adverse health effect, particularly on respiratory systems. There are both anthropogenic and natural sources of acrolein in the environment. Acrolein is produced by combustion sources (e.g. vehicle exhaust, prescribed agricultural burning, cigarette smoke) and industrial sources, including manufacturing facilities of wood products. There is, however, very limited data quantifying the emissions of acrolein from these sources. There are also few reports of ambient levels because of the measurement limitations.
There is a need for air quality instrumentation for acrolein and other toxic air pollutants for routine air quality monitoring in urban areas for health effect assessment, and at specific sites for source assessment studies. The EPA Region 10 has identified as a priority issue the development of a measurement technique for monitoring acrolein. We propose to develop a fast respons novel quantum cascade laser system based on Tunable Infrared Laser Differential Adsorption Spectroscopy (TILDAS). The diversity of sources and the relatively high reactivity of acrolein require a highly sensitive, easily portable, and fast response measurement technique. The proposed acrolein monitor will meet these requirements, achieving sensitivities both in the pares-per-billion range for source monitoring and parts-per-trillion range for ambient monitoring.
The objective of the Phase I Research and Development effort is to determine the feasibility of a real-time mid-infrared TILDAS instrument to monitor acrolein. We will evaluate potential infrared spectral regions to determine the optimum region for acrolein monitoring. We will investigate background suppression techniques which are critical to achieving low detection limit. The Phase II instrument design will be identified in Phase I. The anticipated result of our approach is a robust, sensitive, real-time monitor of acrolein. It will be capable of long term operation in the field or laboratory with minimal maintenance.
There is a need for commercially available air quality instrumentation for acrolein and other toxic air pollutants. The infrared laser detection technique to be developed in this proposal will have wide commercial applications both for routine air quality monitoring and for source assessment of hazardous air pollutants.
Technology keywords
Not reported
Other awards by this recipient
Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.
Research funding history
410 SBIR/STTR records share this UEI (1983–2025). Reported award amounts total $116,799,166. Reported amounts are not federal obligations.
Phases: Phase I, Phase II
Agencies: Department of Defense, Department of Energy, National Aeronautics and Space Administration, National Science Foundation, Environmental Protection Agency, Department of Commerce
Agency intelligence
Environmental Protection Agency
Back to SBIR/STTR Research Awards