TAPERED LINEAR PHASED ARRAY FOR ULTRASOUND HYPERTHERMIA

Award identifier e0cfa7417fdea39c85eb9d53af0800520b2b35049e79896f05a68e4db15a172dAwarding agency Department of Health and Human Services

Award amount

$486,000

Program and phase

SBIR · Phase II

Award year

1989

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
Not reported
Recipient company
Labthermics Technologies, Inc.
Proposal award date
Not reported
Contract end date
Not reported
UEI
Not reported
Solicitation number
Not reported
Topic code
Not reported

Research abstract

THE OVERALL GOAL OF THIS PROJECT IS TO COMPLETE DEVELOPMENT AND TO TEST A NOVEL ULTRASONIC TAPERED LINEAR PHASED ARRAY APPLICATOR FOR HYPERTHERMIA TREATMENT. SUCH AN APPLICATOR WILL ALLOW ELECTRONIC STEERING OF THE FOCUS ALONG A DESIRED PATH WITHOUT THE USE OF A MECHANICAL SCANNING SYSTEM; IT WILL ALSO REMAIN FIXED RELATIVE TO THE PATIENT, MAKING COUPLING EASIER. THE APPLICATOR WILL BE COMPUTER CONTROLLEDSUCH THAT THE SCAN PATH AND/OR INTENSITY CAN BE ALTERED AT ANY TIME DURING TREATMENT TO MAINTAIN A CONSTANT UNIFORM TEMPERATURE. SUCH A SYSTEM IS EXPECTED TO MEET THE REQUIREMENTS FOR CONTROLLED LOCAL HYPERTHERMIA TREATMENT OF DEEP-SEATED TUMORS. EACH ELEMENT OF THE PHASED ARRAY APPLICATOR (64 IN ALL) WILL BE DRIVEN BY A MODULAR HIGH- POWER-MULTICHANNEL RF GENERATOR SIMILAR TO THAT USED IN THE URI THERM-X, INC. SONOTHERM 1000 ULTRASOUND HYPERTHERMIA SYSTEM. INITIAL TESTING OF THE APPLICATOR WILL CONSIST OF EXPERIMENTALLY ACQUIRING FIELD PLOTS AND COMPARING THEM TO THE THEORETICALLY PREDICTED PLOTS. WHEN THE EXPERIMENTAL PHASED ARRAY APPLICATOR IS GENERATING FIELDS AS EXPECTED THEORETICALLY AND THESE FIELDS SEEM TO BE ADEQUATE FOR HYPERTHERMIA APPLICATIONS, TESTS ON PHANTOMS WILL BE INITIATED. FINALLY, THE PERFORMANCE OF THE PROTOTYPE APPLICATOR THAT ELECTRONICALLY SCANS ITS FOCUS WILL BE COMPARED TO THAT OF A MECHANICALLY SCANNED, FIXED FOCUS APPLICATOR FOR VARIOUS SCAN PATTERNS. IF THE PROPOSED PROTOTYPE ULTRASONIC PHASED ARRAY APPLICATOR EXHIBITS HEATING PERFORMANCE AND CONTROL COMMENSURATE WITH CLINICAL NEEDS, PHASE II DEVELOPMENT WILL BE DEVOTED TO THE CONSTRUCTION AND ANIMAL TESTING OF A PROTOTYPE SYSTEM IN PREPARATION FOR TRIALS.

Technology keywords

Not reported

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.