SBIR/STTR Research Award

Paracorporeal Artificial Lung Development

Award identifier aa7e2afaa48641bc11428d5165bd4ff852c2218469510f1779361982a1c5ff6aAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$175,811

Program and phase

STTR · Phase I

Award year

2001

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
MICHIGAN CRITICAL CARE CONSULTANTS, INC.
Proposal award date
Not reported
Contract end date
Not reported
UEI
NVSPCRHNAF11
Solicitation number
Not reported
Topic code
Not reported

Research abstract

DESCRIPTION (Verbatim from the Applicant's Abstract): Despite the widespread success and enthusiasm f single and double lung transplantation, demand for donor lungs has steadily outgrown supply. Currently, the average wait is two years, with 30 percent wait-list mortality. A prototype Paracorporeal Artificial Lung (PAL) was designed and built by MC3 (Ann Arbor, MI) for high gas exchange efficiency and very low blood flow resistance. The initial PAL was implanted by our collaborators (UTMB) in a pulmonary artery-to-pulmonary artery (PA-PA) configuration, and supported gas exchange in normal sheep (N=8) for up to 7 days. Mean pressure gradient at total PA flow across the artificial lung was 8 mm Hg (3 Wood units); 4 of 8 sheep survived complete balloon inflation (full flow) but 4 of 8 sheep were intolerant from right heart failure. Complications included exsanguination (4/8) due to breakage (2 sample ports, 2-cannula disconnection). Therefore, necessary prototype PAL modifications include: 1) a lower resistance gas exchanger with 2) an inflow compliance chamber, and 3) collet-nut cannula connections without blood sample ports. The immediate goal of this research plan is to: Specific Aim 1. Build a working prototype for the modified PAL, based on our initial experience, to incorporate the following design changes 1) lower resistance gas exchanger with 2) inflow compliance chamber and 3) collet-nut cannula connections without blood sample ports. Specific Aim 2. a) Perform 7-day studies in healthy sheep to determine the maximum level of PAL gas exchange performance and hemodynamic augmentation achievable. b) We will utilize our recently developed, clinically relevant (LD50) model of acute respiratory distress syndrome (ARDS) in adult sheep (n=8) to initially evaluate PAL performance during acute respiratory distress syndrome (ARDS) for seven days. For Phase II, we will perform a prospective, randomized outcomes study comparing standardized pressure controlled mechanical ventilation versus PAL in our LD50 and LD100 models of ARDS to determine long-term survival or bridge capability during severe respiratory failure. This project will complete the PAL development and yield patient management and selection protocols for future PAL human safety trials. PROPOSED COMMERCIAL APPLICATION: The commercial potential for the PAL is both immediate and has the potential for significant spin-off technology. The immediate market will be as a bridge to lung transplant. The long term potential is as an alternative to transplant for end-stage lung disease (a much larger population). The research proposed will also undoubtedly benefit the design of routine cardiopulmonary bypass (CPB) oxygenators (300,000 cases a year in the U.S. alone at a market price of $90,000,000).

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Research funding history

68 SBIR/STTR records share this UEI (1991–2023). Reported award amounts total $29,918,691. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Health and Human Services, Department of Defense

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.