SBIR/STTR Research Award

Development of an ABO Incompatibility Stop Device (AISD)

Award identifier 45453bbc0f3018eb71b95c98a9cd5acb1d22041f27798fee77eaa44b9497b639Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$132,391

Program and phase

STTR · Phase I

Award year

2008

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
TRANSFUSION AND TRANSPLANTATION TECH
Proposal award date
Not reported
Contract end date
Not reported
UEI
Not reported
Solicitation number
PHS2007-2
Topic code
Not reported

Research abstract

DESCRIPTION (provided by applicant): This is a Phase 1 STTR application entitled Development of an ABO Incompatibility Stop Device (hereafter AISD) to prevent mistransfusion. Mistransfusion, a term generally used to describe an episode where the wrong p atient receives the wrong blood , occurs for a variety of reasons including improper identification of the intended recipient during initial sample collection for blood typing, improper typing or pretransfusion testing of the blood component or recipient i n the blood bank, or misidentification of the patient recipient and/or the blood unit at the time of initiation of the blood transfusion. Mistransfusion, considered by most authorities to be the leading cause of transfusion-related mortality, has a reporte d estimated incidence approaching 1 in 14,000 units in the United States. A number of technologies exist that are thought to be able to reduce mistransfusion including bar-coding of patient and blood unit identifiers, radio frequency identification (RFID), combination locked pouches that require a special bedside code, and bedside ABO tests that would allow an operator to retype the patient and match the patient blood type with the blood unit label. None of these methods has enjoyed even modest implementati on to date, and each of these methods involves human actions, interpretation, or decision, thus allowing human error. It is human error, then, that leads to the #1 cause of transfusion-associated death. In this application, we describe novel fully automate d, bedside medical device, the AISD, capable of: 1) performing a bedside compatibility test, and 2) preventing a mistransfusion event. This Phase 1 application is offered in a proof of concept format with preliminary data to support that both the concept o f such a device and the proposed AISD design are feasible. The overall goal of Phase I is represented in a single Specific Aim: To design, test, and engineer a bench top prototype AISD consisting of 4 elements: the Red cell Exclusion Filter (REF), Compatib ility Reaction Chamber (CRC), Incompatibility Detector (ID), and Stop Element (SE). Each of these 4 elements which constitute the AISD base unit will be designed, fabricated, tested, and optimized. This will be followed by building a working, bench top pro totype that can be tested in a variety of clinically relevant circumstances (i.e., compatible transfusion combinations [O to A] and incompatible [A to O] combinations) in order to validate function and proof of principle. PUBLIC HEALTH RELEVANCE: While blo od transfusions are life-saving interventions, sometimes incompatible blood is transfused in error and this can lead to death. In fact, this is the #1 complication of blood transfusion. A number of methods have been tried to improve this problem including better training of personnel and barcode identification of patients, but none has worked. In this application, we present a fully automated device that will sample the patient/recipient and the donor blood unit and prove compatibility without human assista nce. If the unit is not compatible, the transfusion is not allowed to proceed. This should stop all mistransfusion and the related deaths.

Technology keywords

Not reported

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.