SBIR/STTR Research Award
Regenerable Electrochemical Spiral Wound Decontamination Cell for Efficient Decontamination of Radionuclides in Water
Award amount
$68,700Program and phase
SBIR · Phase IAward year
2007Award details
- Awarding agency
- Environmental Protection Agency
- Branch
- Not reported
- Recipient company
- ISOTRON CORPORATION
- Proposal award date
- Not reported
- Contract end date
- Not reported
- UEI
- Not reported
- Solicitation number
- Not reported
- Topic code
- Not reported
Research abstract
Water security has become a national priority following the terrorist attacks of September 11, 2001. This proposal specifically addresses the threat of radionuclide contamination, such as that resulting from a terrorist release of radioactive material into the water supply, but is expected to result in technology that is broadly applicable to other water borne contaminants. More specifically, this proposal focuses on cesium-137, a highly water soluble radionuclide which is considered the most likely candidate for use in a radiological dispersal device.
We propose a spiral wound electrochemical flow cell for the removal of radionuclides primarily cesium-137 and secondarily strontium 90 from drinking water. The proposed cell will consist of a flexible electrode sandwich in which one of the electrodes has been plated with nickel hexacyanoferrate (NiHCF), an electrochemically switchable ion exchange material (ESIX). The composite electrode sheet, which also contains a counter electrode and reference electrodes for true three electrode operation, is rolled into a spiral sound cylinder for compactness, throughput, capacity, and ease of manufacture. Contaminated water is fed to one face of the cylinder while holding the potential of the cathode at the designated level to produce clean water at the other end of the rolled electrode. Finally, unlike conventional ion exchange, the ESIX material can be regenerated without using a concentrated regenerant or replacing the ion exchange media; ESIX bed regeneration is achieved through a reversal of the potential on the electrodes. Upon potential reversal, the intercalated cations are eluted into a small volume (e.g. one bed volume of concentrated waste.
The effort builds upon our experience with microfluidic NIHCF electrodes, and aims to transition the technology from a microfluidic plate/frame architecture to a large-scale spiral wound form. The objectives are to fabricate and demonstrate an electrochemical filter element which matches conventional filters form factors while producing far less waste and operating far mor efficiently than either conventional ion exchange or reverse osmosis.
Technology keywords