INDWELLING FISTULA ACCESS DEVICE (IFAD) FOR HEMODIALYSIS

Award identifier 120f1c4c85c7904f6839ffe34ce9c58f75604aa56d089dbdf17a33d374fcc9c1Awarding agency Department of Health and Human Services

Award amount

$50,000

Program and phase

SBIR · Phase I

Award year

1987

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
Not reported
Recipient company
ASH ACCESS TECHNOLOGY, INC.
Proposal award date
Not reported
Contract end date
Not reported
UEI
Not reported
Solicitation number
Not reported
Topic code
Not reported

Research abstract

EFFECTIVE HEMODIALYSIS REQUIRES A BLOOD FLOW OF 250 TO 300 ML/MINUTE. THE USUAL METHOD FOR OBTAINING THIS BLOOD ISTO PLACE TWO LARGE NEEDLES INTO A FISTULA (ARTERIALIZED VEIN) OR A GRAFT (PTFE CONDUIT BETWEEN ARTERY AND VEIN). BOTH NEEDLES ARE REMOVED AT THE END OF EACH TREATMENT. THE OBJECTIVE OF THIS PROPOSAL IS TO FURTHER DEVELOP AN INDWELLING FISTULA ACCESS DEVICE (IFAD) THAT CAN BE INSERTEDINTO A FISTULA OR GRAFT, LEFT IN PLACE FOR SEVERAL WEEKS OR MONTHS, AND USED FOR NUMEROUS HEMODIALYSIS TREATMENTS. BLOOD ACCESS WOULD THEN BE RAPID, PAINLESS, AND BLOODLESS. THE IFAD WILL BE CONSTRUCTED FROM TWO SIZES OF STAINLESS-STEEL NEEDLE STOCK. A 20-GAUGE NEEDLE WITH POINT IS WELDED INTO THE FRONT OF A 17-GAUGE NEEDLE, NEAR A SIDE HOLE IN THE LARGER NEEDLE (FOR BLOOD REMOVAL OR RETURN). THE SMALL NEEDLE IS INSERTED FIRST INTO THE FISTULA OR GRAFT, AND ROTATION BRINGS THIS NEEDLE THROUGH THE SKIN, WHERE A CAP IS PLACED TO CLOSE IT AND TO STABILIZE THE DEVICE. THE ROTATION ALSO BRINGS THE SIDE HOLE OF THE 17-GAUGE NEEDLE INTO THE FISTULA. ANIMAL TESTS WITH A SIMILAR 16-GAUGE DEVICE HAVE SHOWN THAT THE IFAD CAN BE LEFT IN PLACE FOR UP TO 4 MONTHS WITHOUT CLOTTING, PHLEBITIS, OR INFECTION. THIS IMPRESSIVE BIOCOMPATIBILITY IS DUE TO IMMOBILIZATION OF THE DEVICE AND TO AVOIDING THE TRAUMA OF A NEEDLE POINT WITHIN THE FISTULA. DURING THIS PROJECT, IN VITRO TESTS WILL DETERMINE THE HYDRAULIC RESISTANCE OF THE IFAD. ANIMAL TESTS WILL DETERMINE THE LONGEVITY, BIOCOMPATIBILITY, RESISTANCE TO INFECTION, AND EASE OF REMOVAL OF THE DEVICE. IF THESE TESTS ARE SUCCESSFUL, AN INVESTIGATIONAL DEVICE EXEMPTION (IDE) PROPOSAL WILL BE PREPARED FOR SUBMISSION TO THE FOOD AND DRUG ADMINISTRATION FOR HUMAN TESTING OF THE DEVICE.

Technology keywords

Not reported

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.