SBIR/STTR Research Award

Deterministic Radiotherapy Dose Calculation Method

Award identifier a7005553786b83ee4009da62424e9a4ca8d4bac657188bede424084625b9d8b9Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$99,291

Program and phase

SBIR · Phase I

Award year

2005

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
TRANSPIRE, INC.
Proposal award date
Not reported
Contract end date
Not reported
UEI
Not reported
Solicitation number
PHS2005-2
Topic code
Not reported

Research abstract

DESCRIPTION (provided by applicant): A present need exists for the development of accurate and efficient dose calculation methods for clinical treatment planning in external beam radiotherapy. Due to recent advances in image guided localization techniques and the development of more precise beam delivery methods such as Intensity Modulated Radiation Therapy (IMRT) and Stereotactic Radiosurgery (SRS), the potential exists to substantially reduce margins and improve dose conformity. However, most dose calculation methods in clinical use today employ approximations that limit their accuracy and scope of use, especially with narrow beams in the presence of heterogeneities. As a result, the adoption of more accurate methods such as Monte Carlo is seen as highly desirable. However, Monte Carlo calculations can be time consuming, limiting their effectiveness for clinical treatment planning. The application of a novel deterministic dose calculation method, which solves the differential form of the governing transport equations for neutral and charged particles is proposed. As indicated in preliminary studies, this approach has the potential to provide accuracy comparable to detailed Monte Carlo simulations with a substantially faster computational speed. The proposed approach incorporates anisotropic element adaptation to efficiently resolve complex anatomical features and sharp solution gradients, which is aided by the use of higher-order discontinuous finite element methods on variably sized tetrahedral elements. In Phase 1, a proof-of-concept process will be developed to quantify performance for patient specific dose calculations. This will be validated with detailed Monte Carlo results for selected treatment plans incorporating bone, air and lung heterogeneities, using both wide and narrow beams. Success will be measured on performance relative to Monte Carlo, defined in terms of combined speed and accuracy. Potential enhancements to further improve efficiency in Phase 2 will be identified, and an estimate of achievable clinical performance will be provided.

Technology keywords

Not reported

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.