SBIR/STTR Research Award

Carbon Nanotube Field-Emission Micro-focus X-ray Tube

Award identifier 386d50ce46546c9548e5293e81a3075a97aa824f1ba1a94ecedc2412c5378753Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$98,000

Program and phase

SBIR · Phase I

Award year

2005

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
XINTEK, INC.
Proposal award date
Not reported
Contract end date
Not reported
UEI
WH5MKB6692W7
Solicitation number
PHS2005-2
Topic code
Not reported

Research abstract

DESCRIPTION (provided by applicant): Substantial technological growth has spurred a new interest in imaging techniques, and their usage has grown considerably. High-resolution small animal imaging systems have emerged as important new tools for laboratory animal research. X-ray imaging is widely used in diagnostic radiology, biomedical research and a wide variety of industrial applications. We propose to design and construct a portable, low cost micro-focus x-ray tube using the carbon nanotube (CNT) field emission source as the cathode to overcome disadvantages of the hot electron sources in the present x-ray tubes. By implementing the proposed research (Phase I and II), we expect to be able to demonstrate new compact x-ray tube with the following features: high imaging resolution down to 30 um or smaller, electronic controllable effective focal spot in 30 ~ 100 um range, portable device with extended lifetime of up to 3000 hours, capability of electronic triggering the x-ray at the rate of 1-10 millisecond (msec) per image, 100-500 uA tube current with 1% stability under 40-100KVp voltage. The primary application of the proposed x-ray source is for small animal imaging. The major research design and methods to achieve the proposed development goals include: a) Synthesis and processing of proprietary carbon nanotube materials; b) Fabrication of CNT based field emission cathode capable of generating 1-5 A/cm2 field emission current density, c) Integration of gated electron source employing the CNT source technique developed at Xintek, d) Evaluation of the electron emission characteristics including threshold field, current stability, and lifetime, e) Design and construction of prototype portable x-ray device, f) Computer simulation to the electron optics designed to simplify the focus structure, g) Evaluation of the new type x-ray tube by studying the key imaging characteristics: x-ray energy spectrum, flux, high voltage stability, spatial resolution/focal spot, pulsed x-ray radiation with millisecond pulse width.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Research funding history

16 SBIR/STTR records share this UEI (2002–2014). Reported award amounts total $3,673,318. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: National Science Foundation, Department of Health and Human Services, Department of Defense, National Aeronautics and Space Administration, Department of Energy

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.