SBIR/STTR Research Award

Field Deployable, Automatic, EEG Seizure Detector and Brain Dysfunction Monitor

Award identifier d528d82ddcb50b3668a7ff076b0ddc52bb44d058ba8481cbbe3e9c22187364a6Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$2,822,940

Program and phase

SBIR · Phase I

Award year

2006

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
CLEVELAND MEDICAL DEVICES, INC.
Proposal award date
Not reported
Contract end date
Not reported
UEI
LKM3SMX1MMM5
Solicitation number
PHS2006-2
Topic code
Not reported

Research abstract

DESCRIPTION (provided by applicant): The overall goal of this Fast-Track SBIR proposal is to develop a portable, low-cost, field-deployable, automatic EEG-based seizure detector and brain dysfunction monitor for general civilian population under mass casualty conditions. It is envisioned that this system will be used as an essential component of rapid and aggressive management of seizures, crucial to ameliorate neuropathology caused by nerve agent exposure in a terrorist attack. The development of this system will be based on further enhancement and integration of our several highly relevant technologies, including a commercial-grade portable, low cost, and robust intra-operative consciousness monitor that tracks patient's cortical activity in real-time during surgical procedures requiring anesthesia. The seizure detection algorithms will take advantage of our ongoing projects with the NIH and the ARMY where we are developing a novel class of seizure identification algorithms that can operate in real-time on a standard laptop. The robustness of the system will be enhanced by incorporating our novel artifact identification and removal algorithms currently supported by NINDS. The Phase I stage will develop a rugged, portable, field-deployable, seizure detector comprising of an 8- channel EEG device that is attached to a laptop that performs seizure detection and will display the seizure status in graphical format. Phase II will further miniaturize the EEG patient unit which will also contain an onboard data processing capability (DSP) and an attached screen that will display seizure status in real-time. The unit will also contain data storage and a wireless capability allowing it to communicate with a centralized station that can monitor several of these patient units simultaneously. The developed prototypes at the end of each Phase will undergo extensive simulated and actual clinical evaluations. In particular, The Phase II system will be tested in the Emergency Departments (ED) of two major health facilities, The Cleveland Clinic and University Hospitals of Cleveland, with a combined 255 patients who have been admitted to the ED and who are in need of an emergency EEG examination. The portable, low-cost, field-deployable, automatic EEG-based seizure detector and brain dysfunction monitor to be developed under this project is aimed for general civilian population under mass casualty conditions. It is envisioned that this system will be used as an essential component of rapid and aggressive management of seizures, crucial to ameliorate neuropathology caused by nerve agent exposure in a terrorist attack. The same technology is also applicable for EEG monitoring and seizure detection of military personnel subjected to a nerve gas attack in the battlefield. Finally, the developed system can be eventually become part of the general care in the Emergency Department and particularly in patients with altered mental status and those suspicious of having non-convulsive seizures and brain dysfunction.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Research funding history

104 SBIR/STTR records share this UEI (1992–2016). Reported award amounts total $44,360,204. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Health and Human Services, Department of Defense, National Science Foundation, Department of Education

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.