SBIR/STTR Research Award

Breath Ammonia Measurements for Dialysis Assessment

Award identifier a57e8e33f8de31f57ef7d125287ed9a2d615bc5dcdfbc848dd2a1859dbeb11d1Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$108,933

Program and phase

SBIR · Phase I

Award year

2001

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
Pranalytica, Inc.
Proposal award date
Not reported
Contract end date
Not reported
UEI
F27LAD24N4F3
Solicitation number
Not reported
Topic code
Not reported

Research abstract

We propose that breath ammonia is a surrogate measure of nitrogenous waste loading in the blood of patients suffering from End Stage Renal Disease. We present preliminary infrared spectroscopic data of human breath from a limited study of n=7 patients undergoing kidney dialysis. Breath ammonia concentration drops from approximately 2000ppb+/- 10% to approximately 200ppb+/-10% between the beginning and the end of the treatment session. We show correlations with reductions in blood urea nitrogen (BUN: approximately 90mg/dL to approximately 30mg/dL) and creatinine (approximately 14mg/dL to approximately 5mg/dL) determined by assaying blood samples taken at every breath measurement. We propose in Phase I to expand the study to n=50 patients to 1) validate the use of breath ammonia as a surrogate measure of BUN and creatinine, 2) refine breath collection and spectroscopic methods, 3) further miniaturize the spectrometer. We will use the Phase I results to design an n equal to or > 500 Phase II patient study to obtain FDA Approval of the spectrometer and to engineer the system into a package small enough to be 1) incorporated into dialysis machines for continuous in-situ assessment of dialysis efficacy and 2) used in the homes of ESRD patients and those at risk of ESRD, such as diabetics and hypertensives. PROPOSED COMMERCIAL APPLICATIONS: Provide every kidney dialysis patient and nephrologist with an instantaneous measure of the progress and efficiency of dialysis treatment. Substitute regular breath measurement for currently-used infrequent blood panels to determine when to begin and stop treatment. Integrate instrument into dialysis machines for in-situ analysis. U.S. Market: >220,000 dialysis patients treated 3 times per week corresponding to 34.32 million dialysis sessions per year Painlessly assess and screen the well-being of diabetics, hypertensives, and premature babies with potential kidney/liver trouble. U.S. Market > 2,000,000 individuals per year

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Research funding history

20 SBIR/STTR records share this UEI (2001–2019). Reported award amounts total $8,546,953. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Defense, Department of Agriculture, Department of Health and Human Services

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.