SBIR/STTR Research Award

Rapid Exchangeable Bioprosthetic Heart Valve

Award identifier edb600dbe0a8b8158e5b7d559f59c98ce9d7e75978525389b46b333f57fb5ecdAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$212,056

Program and phase

SBIR · Phase I

Award year

2003

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
VALVEXCHANGE, INC.
Proposal award date
Not reported
Contract end date
Not reported
UEI
Not reported
Solicitation number
Not reported
Topic code
Not reported

Research abstract

DESCRIPTION (provided by applicant): Each year, 70,000 patients in the United States need to have their diseased heart valves replaced with artificial devices. Although bioprosthetic valves have few complications and are considered ideal for most patients, they wear out in 12-15 years. Because surgery to replace a worn out bioprostheses carries significant operative mortality, bioprostheses cannot be implanted in patients younger than 65. These patients receive mechanical valves and anticoagulation therapy, and hence suffer the risks of thromboembolism. We have conceived of an alternative approach to dealing with the durability problems of bioprosthetic valves, and the associated risk of reoperation. The VALVEXCHANGE procedure enables tissue-based heart valves to be replaced without conventional open-heart surgery. The novelty of this approach is a two-component valve, consisting of a permanent "docking station" that remains affixed to the patient's aorta, and a collapsible frame that supports the leaflets and plugs into the docking station. Once the original leaflets wear out, they can be quickly exchanged with a new set using minimally invasive surgery. In this Phase I proposal, we aim to (i) develop and fabricate a functioning prototype of the exchangeable valve, (ii) confirm its integrity in a hydrodynamic durability tester, and (iii) evaluate the efficacy of the rapid exchange process in a sheep model. Prototypes will be designed using ProEngineer by way of a subcontract to the Cleveland Advanced Manufacturing Center, and evaluated in a hydrodynamic tester at The Cleveland Clinic Foundation. Final designs will be implanted into a sheep model at the University of Wisconsin. In the animal study, we will be able to determine if the snap-out-snap-in approach is faster and more convenient than conventional suturing. Through these proposed studies, we will demonstrate that (i) we can fabricate the exchangeable heart valve to functional design specifications, and (ii) the two-piece valve concept has specific advantages in the surgical arena. Once we have achieved these milestones, we will apply for Phase II funding.

Technology keywords

Not reported

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.