SBIR/STTR Research Award

High Rate X-Ray Flourescence Detector

Award identifier ffb69e07090cdcb68421c1ddd9cf092fcd81f711fe8d386c43026ff15cb7c412Awarding agency Department of Energy

Award amount

$750,000

Program and phase

SBIR · Phase II

Award year

2007

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Energy
Branch
Not reported
Recipient company
XIA LLC
Proposal award date
Not reported
Contract end date
Not reported
UEI
J26GQK3R6773
Solicitation number
DE-FG01-05ER05-28
Topic code
25

Research abstract

X-ray fluorescence analysis is widely used in basic and applied research, and in commercial process monitoring and quality control operations. Unfortunately, for most experiments that involve fluorescence, the detector system limits the rate at which data can be collected. This project will combine digital processing electronics with a novel silicon drift detector (SDD) design to make a compact, modular, large area detector that provides significantly better resolution and throughput than currently available detector systems, with greater serviceability and lower overall costs. In Phase I, a representative SDD was obtained and measurements were made with digital processing electronics. It then was demonstrated that the electronics could fit within the detector housing, creating a very clean total package with much higher noise immunity than currently available solutions. Phase II will develop a complete multi-element detector array, including seven SDD detector modules, full processing electronics, and associated cooling and power supplies. Host software will be developed to control the new processor. Finally, an ultra-high-speed readout system will be developed, and the software needed by the system will be extended. Commercial Applications and Other Benefits as described by the awardee: Improved detectors should substantially increase the research productivity of fluorescence x-ray experiments at the DOE synchrotron facilities. The detector also should have application in the commercial x-ray market, where high throughput also equates to time and money saved. The technology would allow manufacturers to avoid the problem of combining one company¿s detector system with the processing electronics from another company.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Research funding history

61 SBIR/STTR records share this UEI (1990–2025). Reported award amounts total $18,466,389. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Energy, Department of Health and Human Services, Department of Commerce

Agency intelligence

Department of Energy

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.