SBIR/STTR Research Award

A Cryo-coil MAS 1H/13C/2H/15N Probe for Highest S/N in NMR of Solids

Award identifier 8bdede1a7e8828c135fff3b602bb1338c95a407a9ae64806db6fa89885030877Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$218,459

Program and phase

SBIR · Phase I

Award year

2009

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
DOTY SCIENTIFIC, INC.
Proposal award date
Not reported
Contract end date
Not reported
UEI
ZEWHLT5Y7H33
Solicitation number
PHS2009-2
Topic code
Not reported

Research abstract

DESCRIPTION (provided by applicant): For over three decades, High-Resolution (HR) Nuclear Magnetic Resonance (NMR) has been a leading analytical technique for structure and function elucidation of molecules of all types, large and small, in homogeneous systems. More recently, Magic Angle Spinning (MAS) has been combined with high-field HR-NMR to extend the technique to inhomogeneous systems, such as human and animal tissues. The 1H HR-MAS spectrum of malignant breast cancer tissue shows dramatically increased levels of phosphocholine compared to nonmalignant breast tissue, and it appears likely that other unambiguous markers can be identified for many other pathologies if the signal to noise ratio (SNR) of the HR-MAS probe can be increased sufficiently. MAS is also utilized by thousands of NMR researchers in fields such as macromolecule structure determination, organo-metallo-complexes, and membrane proteins. HR NMR probes for liquids have become available with cryogenically cooled sample coils that are revolutionizing the field of NMR owing to their factor-of-four improvement in SNR. Greater improvements in SNR appear likely in HR-MAS. Our work thus far demonstrated a factor-of-three improvement in SNR in room temperature MAS experiments by cryogenically cooling the sample coil and tuning elements to 25 K while using a standard preamp with noise figure (NF) of 1.0. Another factor-of-two increase in SNR is expected by developing a cryogenically cooled low noise preamp with noise figure below 0.3 and other improvements. The rotating-frame field strength (B1) produced in the sample was severely limited by the poor high-voltage breakdown characteristics of capacitors used in the circuit. We present here, the basis for increasing the B1 field strength from 30 kHz to over 70 kHz on all channels by developing ultra-high Q ceramic disc capacitors that will handle peak voltages in excess of 3.5 kV. Substantial improvements in spinning at temperatures below 90 K will also be developed, which gives further gains in S/N in many systems and improved information on molecular dynamics. PUBLIC HEALTH RELEVANCE: Nuclear magnetic resonance (NMR) has been one of the most effective analytical tools for determining the structure of complex molecules in biology, chemistry, and medicine, but the NMR technique has had limited success for the very large molecules that are not soluble in suitable liquids. The instrument development proposed herein, called a CryoMAS NMR probe, if successful, will reduce the amount of time needed on very expensive NMR spectrometers by a factor of 30 to 100 (from months to days or hours) and thus make it practical to determine the structures of hundreds of thousands of biologically and chemically important macro-molecules for which structures are currently unknown. This is important to drug developments, catalysts, and enzymes, to name but a few.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Research funding history

44 SBIR/STTR records share this UEI (1985–2025). Reported award amounts total $25,710,711. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Health and Human Services, Department of Defense, National Science Foundation, Department of Energy

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.