SBIR/STTR Research Award

High Precision Integrated Beam Position and Emittance Monitor

Award identifier cce084985a4e3739dfb074a839d981fced517149129028bb37f79d38c4bad958Awarding agency Department of Energy

Award amount

$749,999

Program and phase

SBIR · Phase II

Award year

2004

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Energy
Branch
Not reported
Recipient company
Far-Tech, Inc.
Proposal award date
Not reported
Contract end date
Not reported
UEI
LZ6MNQGKZSV3
Solicitation number
DOE/SC-0059
Topic code
44

Research abstract

72755-Beam position and emittance are critical parameters for accelerator applications, including colliders and radiation generation, as in free-electron lasers. A high precision emittance measurement requires precise beam position at the measurement location. At present there is no existing technique, commercial or otherwise, for non-destructive, pulse-to-pulse, simultaneous beam position and emittance measurement. This project will develop a high precision, cavity-based system for simultaneous, pulse-to-pulse beam position and emittance measurements, without beam interception or moving parts. A multi-cavity standing wave structure will be designed, fabricated, and tested, in which the quadrupole and the dipole standing wave modes resonate at harmonics of the beam operating frequency. Phase I designed an optimized 9-cavity standing wave system for simultaneous high precision beam position and emittance measurements. An integrated system was designed so that the quadrupole of the system operates with the pi-mode resonating at the 16th harmonic of the bunch frequency at the Next Linear Collider (NLC), and with the 3pi/4 dipole mode resonating at 12th harmonic. The output field amplitude of the system was close to 9 times that of a single cavity system, resulting in better resolution. In Phase II, the 9-cavity standing wave structure will be fabricated. The complete system will be tested using the beams at the NLC Test Accelerator at the Stanford Linear Accelerator Center. Commercial Applications and Other Benefits as described by awardee: The high precision, integrated, position-emittance measurement technique should be applicable to all particle accelerators where maintaining beam quality is crucial, from high energy physics accelerators to medical application accelerators. The system should offer superior functionality (pulse-to pulse resolution) at a much lower cost (a factor of ten or more) compared to presently available wire scanner systems.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Research funding history

79 SBIR/STTR records share this UEI (1995–2019). Reported award amounts total $24,887,995. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Energy, Department of Defense

Agency intelligence

Department of Energy

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.