SBIR/STTR Research Award

A SOFT X-RAY INTERFEROMETER FOR THE MEASUREMENT OF MATERIAL OPTICAL CONSTANTS

Award identifier 2cd7d03127d83f712a2e7b13b61dc091d3d2054b3c6dfd8030f9da3799f949d0Awarding agency National Science Foundation

Award amount

$267,840

Program and phase

SBIR · Phase II

Award year

1985

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
National Science Foundation
Branch
Not reported
Recipient company
Kms Fusion Inc
Proposal award date
Not reported
Contract end date
Not reported
UEI
Not reported
Solicitation number
Not reported
Topic code
Not reported

Research abstract

SOFT X-RAY INTERFEROMETRY WILL DIRECTLY MEASURE THE REAL PART OF A MATERIAL'S INDEX OF REFRACTION, SATISFYING A GROWING NEED FOR ACCURATE OPTICAL CONSTANTS IN THE 8-100 A REGION. AS SYNCHROTON SOURCES IN THIS X-RAY RANGE HAVE BECOME WIDELY AVAILABLE, COMMERCIAL RESEARCH HAS MOVED INTO SOFT X-RAY MIRROR DEVELOPMENT, X-RAY LITHOGRAPHY, AND SPECTROSCOPY. BOTH THE DIRECT REDUCTION OF DATA AND THE FABRICATION OF X-RAY OPTICAL TOOLS FOR THIS RESEARCH REQUIREA DETAILED KNOWLEDGE OF SPECIFIC MATERIAL INDICES OF REFRACTION AT VARIOUS WAVELENGTHS. PRESENT INACCURACIES IN THE REAL PART OF THE INDEX OF REFRACTION HAVE, FOR INSTANCE LIMITED THE USEFULNESS OF NORMAL INCIDENCE MULTILAYER X-RAY MIRRORS. ONE CANNOT RELIABLY DESIGN LAYER THICKNESS TO OVERLAP PEAK MIRROR REFLECTIVITY WITH DESIRED X-RAY LINE SPECTRA. TWO DESIGN CONCEPTS WILL BE EVALUATED IN THIS PROPOSAL FOR A SOFT X-RAY INTERFEROMETER. THE FIRST DESIGN IS BASED UPON OUR EXPERIENCE AT KMS FUSION WITH X-RAY TRANSMISSION GRATINGS. THE GRATINGS WIIL PERFORM LIKE A CRYSTAL IN LAUE GEOMETRY, SPLITTING AND REMERGING THE X-RAY WAVEFRONT. THE SECOND DESIGN IS MORE CONVENTIONAL, BASED UPON A FRESNEL MIRROR INTERFEROMETER. WE WILL CALCULATE AND ANALYZE THE PERFORMANCE CHARACTERISTICS OF THESE TWO INSTRUMENTS, BASED UPON THE SPATIAL COHERENCE REQUIREMENTS THEY IMPOSE UPON THE SOFT X-RAY SOURCE. THE BETTER CONCEPT WILL BE CHOSEN AND DESIGNED FOR APPLICATION ON EITHER OUR KMSF SOFT X-RAY CALIBRATION FACILITY OR ON A SYNCHROTON RADIATION SOURCE. MEASURED OPTICAL CONSTANTS WILL THEN BE COMPARED DURING PHASE II TO THE MOST RECENT SUB-KEV X-RAY TABULATIONS.

Technology keywords

Not reported

Agency intelligence

National Science Foundation

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.