SBIR/STTR Research Award
Developing a ClO2 Compliance Service: Minimizing Water Borne Microbial Infection
Award amount
$150,000Program and phase
SBIR · Phase IAward year
2011Award details
- Awarding agency
- Department of Health and Human Services
- Branch
- National Institutes of Health
- Recipient company
- NOBULL INNOVATION, LLC
- Proposal award date
- Not reported
- Contract end date
- Not reported
- UEI
- Not reported
- Solicitation number
- PA10-050
- Topic code
- NIEHS
Research abstract
DESCRIPTION (provided by applicant): The US Center for Disease Control (CDC) estimates that more than 1.7 million healthcare associated infections (HAI) are acquired in US hospitals every year, resulting in approximately 100,000 deaths and adding 30-40 billion of direct treatment expense to the nation's healthcare costs (1). Microbial pathogens from tap water are a significant source of HAI (2). Chlorine dioxide (ClO2) (CD) is a chemical disinfectant used to treat public drinking water supplies, primarilyby municipal drinking water utilities. On-site, systemic application of CD, a relatively recent practice, has proven uniquely effective for controlling waterborne pathogens in healthcare facilities (3).CD treatment of institutional water is covered by thesame rules that apply to municipal drinking water treatment systems; Federal regulatory requirements include daily monitoring of CD and its by-product, chlorite ion (ClO2-) (CI) (4). In order to comply with regulations, water samples are collected manuallyfrom taps at specified locations and transported to a centralized location for chemical analysis. The overall objective of the project is an integrated, fully automated, hardened system (System) that can perform all monitoring, recordkeeping and reportingfunctions required by US government regulations covering CD treatment of domestic water supplies. Principle components of the System are: (1) automated water sampling and flow control, (2) analytics, and (3) data management. Water sampling and flow control will incorporate recent advancements in Flow Injection Analysis (FIA), a rigorous methodology characterized by automated handling of sample and reagent solutions with strict control of reaction conditions (5). Analytics will include a proprietary electrochemical device (EC Probe) that is enabled by the research team's seminal innovations in solid-phase electrolytes and sol-gel process technology. This Phase I SBIR proposal (Proposal) has three Specific Aims: (1) optimize the EC Probe and flow system for long-term use under intended conditions; (2) design, build and test an integrated, fully-automated System; and (3) develop performance data that will demonstrate the value of engineering and cost-effective production of a standardized, commercial system infuture phases. PUBLIC HEALTH RELEVANCE: CDC estimates that over 1.7 million infections per year are acquired by patients while they are in US hospitals. These healthcare associated infections (HAI) many of them caused by microbial pathogens from tapwater result in nearly 100,000 deaths, an estimated 30-40 billion in direct treatment costs alone. are a significant, documented source of HAI. Upon completion, of this project the developed system-enabled compliance services would allow US healthcare institutions to implement Chlorine Dioxide water treatment, thereby substantially eliminating an entire class of HAI and saving tens of thousands of lives and billions of dollars per year.
Technology keywords
Not reported
Awards with the same topic code
Verified by an exact topic code match. This is not a text-similarity match.
- Bioinspired Green Glycolipids as Fugitive Dust Mitigation Agents
- Supercritical Fluid Cartridges for Calibration of Air Pollution Sensors
- Weight Loss and Endocrine Disrupting Chemicals (EDCs): Lifestyle interventions to lose weight and reduce EDC exposure in individuals with overweight/obesity
- High-Resolution Ground-Level AQ Monitoring System Using Hyper-local Low-cost Sensor Nodes and AI Forecasting
- Bringing PFAS Monitoring Home: An Integrated Magnetic Nanoparticle and Lateral Flow Assay System