SBIR/STTR Research Award

Implantable, FET-based, Multimodal Sensor for Biomedical Applications

Award identifier 20e845d0f695890e5323c5d133937faf493197672d92975fe3c36a4154e48d50Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$149,957

Program and phase

SBIR · Phase I

Award year

2008

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
ITN ENERGY SYSTEMS, INC.
Proposal award date
Not reported
Contract end date
Not reported
UEI
PPC3ZC9W3NJ3
Solicitation number
PHS2007-2
Topic code
Not reported

Research abstract

DESCRIPTION (provided by applicant): As the need to record directly from the brain in humans and animals has grown over the last two decades, especially in candidate patients requiring resective epilepsy surgery, so too has the need for real-time, multi- modal analysis within an implantable package. ITN Energy Systems, in collaboration with Yale University Epilepsy Program, and Ad-Tech Medical Instruments Corporation, electrode manufacturer and end-user, will bring their unique expertise in biocompatible materials and sensors, nanoscale electronics, neurosurgery, neuroscience, and manufacturing, marketing and commercialization of brain implantable electrodes to developing a next generation, implantable sensor system. The goal of this Phase I project will b e to develop a multimodal depth electrode to allow us to more fully map the seizure onset area in patients. The multimodal electrode will be an enhancement of the existing Spencer depth electrode to allow recording of icEEG, pH and potassium ([K+]). Each s ensor, as part of a large, addressable (multiplexed) array, will utilize a field effect transistor (FET) to transduce the electrical signal (induced surface charge) from the biological parameter of interest (i.e., ions such as hydrogen (pH) or potassium, a nd icEEG) into a direct and label-free' electrical readout without the use of bound dyes or fluorescent optical probes. The sensors for these modalities will be co-localized and will all interface with conventional data collection equipment. The device wi ll initially be tested in rats to ensure that the system is feasible for human use. A comparison of the measured pH and K+ will be made between the multimodal electrode and conventional measurements in acute and chronic in vivo studies. These rat studies w ill be critical in determining the refinements needed to be addressed as part of a Phase II trial aimed at using this technology in patients. Anticipated Phase 2 efforts will move the device towards use in patients as well as replace the current electrodes with completely wireless devices which can continuously and synchronously sample the specified modalities in real-time with a battery-free solution, and wirelessly transmit the measures directly to a single computer port in digital format without any inte rvening hardware. PUBLIC HELATH RELEVANCE: This project proposes the design and testing of a modified depth electrode to directly measure electrical activity, potassium, and pH from the brain. Such a depth electrode may expand the use of conventional depth electrodes in the localization of the seizure onset region in medically intractable epilepsy patients requiring surgery, the monitoring of brain trauma, and the understanding of other neurological disorders. The proposed battery-free semiconductor electro nics based solution will facilitate integration into conventional data collection equipment to create a low cost, biocompatible diagnostic system that can be actuated and interrogated from outside the brain.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Research funding history

96 SBIR/STTR records share this UEI (1995–2016). Reported award amounts total $24,219,549. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Defense, Department of Energy, National Science Foundation, National Aeronautics and Space Administration, Department of Health and Human Services, Environmental Protection Agency

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.