SBIR/STTR Research Award

TRANSCUTANEOUS INERT GAS MONITOR

Award identifier 05e8c93c58a2499dc6ce1cba97439018ef0524f33a6647447bbe2e8025c0d78aAwarding agency Department of Health and Human Services

Award amount

$50,000

Program and phase

SBIR · Phase I

Award year

1988

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
Not reported
Recipient company
MEDICAL PHYSICS, INC.
Proposal award date
Not reported
Contract end date
Not reported
UEI
Not reported
Solicitation number
Not reported
Topic code
Not reported

Research abstract

ARTERIAL OXYGEN MEASUREMENTS (OBTAINED INVASIVELY) ARE FREQUENTLY USED FOR MEASURING THE PHYSIOLOGICAL OR "EFFECTIVE" SHUNT FRACTION RESULTING FROM GAS EXCHANGE UNITSHAVING LOWER THAN AVERAGE VENTILATION/PERFUSION RATIOS. A METHOD EMPLOYING INERT GAS INSERTION AND BLOOD CONCENTRATIONMEASUREMENT (BOTH INVASIVE) OF THE INERT GASES HAS DEMONSTRATED THE CAPABILITY OF MEASURING THE DISTRIBUTION OFLOW UNITS AND ACCURATELY PREDICTING THE RESULTING REDUCED ARTERIAL OXYGEN CONCENTRATION. THE PURPOSE OF THIS PROPOSAL IS TO DEMONSTRATE THE FEASIBILITY OF DEVELOPING A NONINVASIVE MEANS OF BOTH INERT GAS INSERTION AND ARTERIAL BLOOD CONCENTRATION MEASUREMENT FOR THE PURPOSE OF MONITORING THE SHUNT FRACTION NONINVASIVELY. A TRANSCUTANEOUS METHOD, ANALOGOUS TO THE TRANSCUTANEOUS METHOD FOR OBTAINING ARTERIAL OXYGEN ESTIMATES IS TO BE EMPLOYED. AN IMPORTANT DIFFERENCE IS THAT INERT GASES ARE UNDISTURBED BY TISSUE METABOLISM, WHILE SKIN METABOLISM, COUPLED WITH AN UNCERTAIN SKIN PERFUSION, CAN DEFEAT THE INTENT OF THE OXYGEN MEASUREMENTS. THIS GIVES THE INERT GASTRANSCUTANEOUS APPROACH A MAJOR ADVANTAGE IN THAT IT SHOULD NOT BE DEFEATED BY PHYSIOLOGICAL UNCERTAINTIES; HOWEVER, THEMAJOR PROBLEM WITH THE APPROACH IS THAT SENSITIVITY REQUIREMENTS FOR THE SENSING UNIT EXCEED THE MINIMUM DETECTION LIMITS FOR THE MOST SENSITIVE GAS SENSORS AVAILABLE. THE MAJOR OBJECTIVES OF THE PROPOSAL ARE 1) TO EXPERIMENTALLY VERIFY THE SENSITIVITY REQUIREMENTS FOR THE METHOD, AND 2) CONSTRUCT A WORKING MODEL OF A SENSING DEVICEWHICH MEETS THESE SENSITIVITY REQUIREMENTS. A TECHNICALLY FAVORABLE FEATURE OF THE METHOD IS THAT ITS ACCURACY DEPENDSPRIMARILY ON GAS MEASUREMENT RATIOS AND THE RATIOS OF MEMBRANE SOLUBILITIES OF THE VARIOUS GASES.

Technology keywords

Not reported

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.