SBIR/STTR Research Award

Dynamically Focused High Frequency Ultrasound Transducer

Award identifier f6080dd29692a3e83b826747906e2fd6e471537f26ce15b7b793414ccd92bbfeAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$106,556

Program and phase

SBIR · Phase I

Award year

2005

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
TRS CERAMICS, INC.
Proposal award date
Not reported
Contract end date
Not reported
UEI
PMYKUK6KNB75
Solicitation number
PHS2005-2
Topic code
Not reported

Research abstract

DESCRIPTION (provided by applicant): Electroactive polymers will be investigated as a novel means to dynamically focus high frequency (>30 MHz), single element ultrasound transducers meant for biomedical imaging. Commercial ultrasound array technology has been limited to 20 MHz or less, and though current work is increasing the operating range, the frequency of experimental arrays still lags far behind the 50 MHz+ range necessary to achieve an adequate resolution. Single element transducers are capable of these frequencies, however, these devices only have one focus. As the lateral resolution is increased, the depth of field decreases, forcing mechanical translation along the axis to achieve the desired full image. However, by using electroactive polymers as a back plate, and air as a backing for P(VDF-TrFE) piezoelectric polymer, it will be possible to dynamically change the curvature of single element transducers, thus allowing for focusing at different depths. Using a voltage source, the electroactive polymers can change area by as much as 100%, and when using it as a diaphragm, it effects different curvatures depending upon the amplitude of the voltage. This will allow the fabrication of single element transducers with operating frequencies >30 MHz that provide dynamic focusing for high resolution imaging in applications such as ophthalmology and dermatology. For the Phase I effort feasibility will be demonstrated by fabricating a single element 30 MHz transducer using the electroactive polymer as a back plate. In Phase II, the technique will be expanded to fabrication of higher frequency devices (>50 MHz) and the feasibility for real-time imaging of biological tissues will be tested.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Research funding history

129 SBIR/STTR records share this UEI (1991–2017). Reported award amounts total $37,410,092. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Defense, National Aeronautics and Space Administration, Department of Health and Human Services, National Science Foundation, Department of Energy

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.