SBIR/STTR Research Award

A system to monitor the inlet pressure of rotary blood pumps

Award identifier 6962f56581ea482d09910127074f1ce9f4c6bb072b58a8368aa46a12dca1c25dAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$85,747

Program and phase

SBIR · Phase I

Award year

2008

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
WHALEN BIOMEDICAL, INC
Proposal award date
Not reported
Contract end date
Not reported
UEI
Not reported
Solicitation number
PHS2007-2
Topic code
Not reported

Research abstract

DESCRIPTION (provided by applicant): Axial flow rotary blood pumps have been successfully introduced clinically to provide prolonged mechanical circulatory support, but these devices do not provide load-responsive mechanisms for adjusting pump performance to match venous return and changes in physiologic demand. Most of these devices operate at an adjustable fixed speed, and they have the potential to generate excessive suction pressures that can have serious consequences for the patient. A new device is pr oposed to monitor the inlet pressure in rotary blood pumps to improve their safety and efficacy. Conventional strain gauge transducers are subject to drift and have stability issues that make them unsuitable for long-term implantation. The proposed device employs a comparatively large displacement diaphragm in an elliptical cross-section conduit whose excursion is sensed by a planar transformer system operating at radio frequencies. There is no direct physical contact with the moving diaphragm. Unlike contr ol algorithms that infer hemodynamic conditions at the pump inflow from parameters such as the motor current, the proposed device will enable the development of control systems that dynamically adjust pump speed to avoid excessive suction pressures and opt imize pump blood flow. In essence this will make these devices operate similar to Starling's law devices in which the available blood at the inflow determines the pump output. In Phase I we will design the new inlet pressure sensor and evaluate its static and dynamic performance to evaluate its applicability for controlling a rotary blood pump. A demonstration of feasibility will consist of showing that the device accurately measures inlet conduit pressure and that it has a response time that will permit au tomatic speed control on a beat-by-beat or short-term averaged basis. PUBLIC HEALTH RELEVANCE The proposed device is an electromechanical component designed to measure pressure in the inlet conduit of a blood rotary pump in order to prevent excessive sucti on pressures. The device output will be referenced to intrathoracic pressure. It works by monitoring the deflection of an elliptical cross section elastomeric conduit in response to changes in its internal pressure. This deflection is measured using a plan ar transformer system operating at radio frequencies transparent to body tissues. No direct electrical or physical connection to the moving wall of the conduit is required. The output of the device will be usable as a control signal that may be employed to adjust the pump speed to prevent the development of excessive negative pressures in the pump inflow conduit, left ventricle, and upstream vasculature.

Technology keywords

Not reported

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.