SBIR/STTR Research Award

Photochromic Intraocular lens (Phase II)

Award identifier 07f74454237f360ede50aed77155c29696255e641c1016faa47b976576a8226bAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$1,208,750

Program and phase

SBIR · Phase II

Award year

2010

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
MEDENNIUM, INC.
Proposal award date
Not reported
Contract end date
Not reported
UEI
F2Y3SK2F8W34
Solicitation number
PHS2010-2
Topic code
NEI

Research abstract

DESCRIPTION (provided by applicant): There is mounting evidence that blue light, like UV light, presents a hazard to the eye of the aging population.1-9 Yellow intraocular lenses (IOLs), which absorb blue light, mimic the transmission characteristics of an aged human crystalline lens and aim to protect lipofucsin-containing retinal pigment epithelial cells from being damaged by blue light. Recent studies indicate that a blue-light-absorbing IOL may reduce the risk for macular degeneration or its progression.2,3,6-11 Most importantly, a recent European Eye Study(October, 2008) involving 4753 participants aged 65 or older found a significant association between blue light exposure and neovascular or early AMD in individuals in the quartile of lowest antioxidants levels in their blood stream; the study concluded that the general population should use ocular protection and follow dietary recommendations for key antioxidant nutrients.12 Accordingly, yellow IOLs are increasingly used by surgeons; approximately half of the IOLs used in the US are blue-light-blocking. However, two recent intra-individual comparison studies13-14 in humans found that yellow IOLs have lower visual acuity and poor color vision perception compared with the clear lens (non-yellow) counterpart under low light conditions. Recent studies also suggested that patients with yellow IOLs may suffer from disrupted circadian rhythm.15 AuriumTM, a photochromic hydrophobic acrylic IOL, is designed to provide all benefits of a yellow IOL without any of its compromises. The design was based on the fact that blue-light intensity in outdoor sunlight is about 10 times stronger than indoor light wherein blue-light is weak and often necessary for good vision (Fig. 1).16 AuriumTM remains clear indoors while outdoors, where both UV and blue light are intense and harmful, it turns yellow and blocks both UV and blue light. Figure 1. Blue Light Intensity: Sunlight scale is on right; indoor light scale is on left All SBIR Phase I experiments have been successfully completed: AuriumTM is biocompatible and photochemically stable; AuriumTM meets all ISO requirements for IOLs and a CE Mark has been obtained. Now we apply for a SBIR Phase II grant to obtain an Investigational Device Exemption (IDE) for the US market. PUBLIC HEALTH RELEVANCE: Approximately half of 3 million cataract procedures in the US use yellow intraocular lenses (IOLs) which reduce the risk of or slow the progression of macular degeneration, 1-7 a major cause for blindness among population over 50.17, 18 Yellow IOLs achieve this by blocking hazardous blue light in addition to UV but they also lower night vision and color perception for patients.12,13 AuriumTM, a photochromic IOL preserves all the benefits of a yellow IOL without any of its compromises and may become a standard for future IOLs.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

3 SBIR/STTR records share this UEI (2004–2010). Reported award amounts total $1,468,073. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Health and Human Services

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.