SBIR/STTR Research Award

Fast Neutron Imaging Scintillator with Low Sensitivity to Gamma Radiation

Award identifier 118078496132dfc73d0f5401c7e99f9797c04a1b93bcd7a935748f08822f9159Awarding agency Department of Energy

Award amount

$749,999

Program and phase

SBIR · Phase II

Award year

2007

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Energy
Branch
Not reported
Recipient company
RADIATION MONITORING DEVICES, INC.
Proposal award date
Not reported
Contract end date
Not reported
UEI
SCKQA85YU4U4
Solicitation number
DE-FG01-05ER05-28
Topic code
25

Research abstract

The detectors available for neutron radiation are still inadequate, primarily limited by the available scintillators. Scintillators that can simultaneously provide high spatial resolution, high neutron detection efficiency, low gamma sensitivity, and fast response time do not exist. This project will develop a structured scintillator that channels light to a digital optical detector, promoting very high spatial resolution, even for the thick scintillators needed for high detection efficiency. The structured scintillator will be inexpensive, will have low gamma sensitivity, and will have a response time of 2 ns. Phase I demonstrated the feasibility of producing the structured scintillator. High spatial resolution and fast decay time were demonstrated, with excellent luminescence under neutron excitation. Phase II will optimize scintillator compositions and parameters of the process. A special neutron-sensitive glass, for producing neutron-sensitive capillary array substrates, will be developed. This new development will improve the overall neutron stopping power of the proposed sensors. Large area prototype sensors will be fabricated and evaluated at neutron beam facilities, in order to demonstrate their efficacy for incorporation into advanced high resolution neutron detectors. Commercial Applications and Other Benefits as described by the awardee: The structured scintillator should find widespread applications in neutron radiography and neutron crystallography. Detectors based on the proposed scintillator could be employed at any neutron source facility and would help advance basic research in material science, protein mechanisms research, and drug design. Further applications could be found in non-destructive testing and secuity scanning at entry ports and strategic facilities.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Research funding history

930 SBIR/STTR records share this UEI (1983–2026). Reported award amounts total $346,950,619. Reported amounts are not federal obligations.

Phases: Phase I, Phase II, Phase II – Direct to Phase II

Agencies: Department of Energy, Department of Health and Human Services, Department of Defense, National Aeronautics and Space Administration, National Science Foundation, Department of Homeland Security

Agency intelligence

Department of Energy

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.