- Awarding agency
- Department of Health and Human Services
- Branch
- National Institutes of Health
- Recipient company
- DANYA INTERNATIONAL, INC.
- Proposal award date
- Not reported
- Contract end date
- Not reported
- UEI
- ZKHKBTNLLKJ7
- Solicitation number
- Not reported
- Topic code
- Not reported
Research abstract
DESCRIPTION (Applicant's abstract): The power of polymerase chain reaction
(PCR) as an analytical tool has been widely tested. Recently, many clinical
diagnostic procedures used especially for screening several types of cancer, a
wide range of bacterial, viral and parasitic diseases, individual
identification in paternity testing, forensic analysis, and tissue typing have
started employing PCR technology. Despite the invention of PCR 14 years ago,
most researchers and diagnostic labs conduct PCR analyses one step at a time,
with manual transfers and dedicated, single-function instruments at each step.
Furthermore, both extensive manual handling and the physical heat-transfer
constraints in the thermal cycling step, can contribute to 1/2 to two day long
PCR tests. Although there are some automated tools available to reduce the
manual work at each step, there are currently no cost effective instruments
that completely automate the PCR protocol in a flexible manner. This contrasts
with many of the completely automated non-PCR-based diagnostic instruments in
the modern clinical labs. We propose to apply several recent advances in small
sample handling, fast thermal cycling and general sample processing to the PCR
protocol in order to speed analysis and reduce costs and manual labor. A
technician would simply load a plate of DNA templates and a plate of the
required PCR primers, then start the instrument. The instrument would precisely
aspirate the required volume of each sample, then perform the thermal cycling,
post-PCR cleanup, detection and results-tracking steps in a completely
automated fashion, offering full automation. The instrument would reduce entire
test costs (reagents, disposables and labor) by a factor of 20 or more.
Considering the wide applications of PCR, we propose to make the instrument
flexible (e.g., different types of detection protocols with few changes to the
instrument hardware). The basis of the new instrument is to perform all
functions: mixing, thermal cycling, clean up, detection and sterilization
within the same set of nano-pipetter reaction vessels. In the Phase I, the
target is on two PCR-based protocols: one for DNA diagnostics and one for SNP
analysis. The key features of the proposed instrument, namely fast,
small-volume PCR, fluorescent detection and reaction chamber cleaning will be
developed and demonstrated within the Phase I project. Phase II will entail the
development of a complete prototype instrument and demonstration of high-speed,
low-volume processing of samples using selected protocols.
PROPOSED COMMERCIAL APPLICATION:
This work will result in advanced-performance commercial PCR analysis instruments.
These will allow researchers to more rapidly make important discoveries using high-throughput
screening assays and be the basis for an efficient and cost effective system for genetic and
infectious disease diagnosis.
Technology keywords
Not reported
Other awards by this recipient
Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.
Research funding history
85 SBIR/STTR records share this UEI (1997–2010). Reported award amounts total $22,941,286. Reported amounts are not federal obligations.
Phases: Phase I, Phase II
Agencies: Department of Health and Human Services
Contractor profile
DANYA INTERNATIONAL LLC
Historical federal award activity, when published, is on that contractor profile. Matched by UEI only.
Agency intelligence
Department of Health and Human Services
NAICS intelligence
This classification comes from the contractor profile, not from the SBIR award record.
Contractor industry classification NAICS 518210
Back to SBIR/STTR Research Awards