SBIR/STTR Research Award
Novel Assay for Ethylene Glycol Toxicity
Award amount
$0Program and phase
SBIR · Phase IAward year
2001Award details
- Awarding agency
- Department of Health and Human Services
- Branch
- National Institutes of Health
- Recipient company
- MICRONIX, INC.
- Proposal award date
- Not reported
- Contract end date
- Not reported
- UEI
- Not reported
- Solicitation number
- Not reported
- Topic code
- Not reported
Research abstract
DESCRIPTION: (Applicant's abstract) Poisoning from ethylene glycol is a
potentially lethal medical emergency but can be treated effectively when
recognized early. Conversely, when diagnosis is late, the outcome is usually
poor. The major pathogenic factor is metabolic acidosis from glycolic acid
(glycolate). Because laboratory testing for ethylene glycol and glycolate is
severely restricted, timely diagnosis depends on comparatively nonspecific
physical signs and laboratory tests.
Lack of access to specific testing and need for differentiation from conditions
featuring similar symptoms constitute a unique medical dilemma. Recognizing
these deficiencies we propose to develop novel, specific enzymic assays for
ethylene glycol and glycolate. Two product configurations are perceived: 1)
aqueous reagents for existing clinical analyzers (serum, quantitative); 2) a
dry-chemistry, dual-analyte point-of-care testrip method (whole blood,
semi-quantitative).The POC method is a dual-analyte test tab device for the
simultaneous estimation of ethylene glycol and glycolate from approximately two
(2) microliters of whole blood without centrifugation or any other form of
sample or reagent handling. To make such a level of miniaturization and
simplicity feasible, we have developed a capillary fill sampling technique
permitting specimen dosing, plasma separation, and red cell removal in one
wholly integrated step. Because of rapid metabolism of (flontoxic) ethylene
glycol and the longer half life of (toxic) glycolate, the latter provides
better prognostic information and improved clinical sensitivity, especially
late post-ingestion. Thus, rapid and simultaneous availability of test results
for both analytes expands the window of diagnostic/therapeutic opportunity.
Socioeconomic benefits are: 1) reducing expensive gas chromatographic
screening, confirmatory and other testing; 2) averting late or unnecessary
treatment; 3) cutting intensive care and hospital stay; 4) abating long term
morbidity (renal dialysis).
PROPOSED COMMERCIAL APPLICATION:
Most current gas chromatographic screening and confirmatory methods for ethylene glycol
require derivatization, sample pretreatment and special columns. Direct methods are fraught
with analytical problems such as peak overlap and trailing. Cases have been reported where
other compounds were identified as ethylene glycol with serious consequences. All methods
require specialized equipment unavailable in most laboratories, are technically demanding,
time consuming, and relatively insensitive. For these reasons access to timely and reliable
testing for ethylene glycol is extremely limited. Testing for the clinically more sensitive and
relevant toxic metabolite glycolic acid is essentially non-existant. Not a single routine clinical
analyzer currently exists offering either an ethylene glycol or glycolate method. The
proposed products would solve these problems.
Technology keywords
Not reported