SBIR/STTR Research Award

SBIR Phase I: Novel Sample Introduction Technique for ICP-MS/AES using a NanomiserTM Device for Spray Formation

Award identifier 729c94899e8feef2c129b1897229c3a5bc0348173553209b3fbb665bf4895aa8Awarding agency National Science Foundation

Award amount

$100,000

Program and phase

SBIR · Phase I

Award year

2003

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
National Science Foundation
Branch
Not reported
Recipient company
CCVD, Inc dba MicroCoating Technologies (MCT)
Proposal award date
Not reported
Contract end date
Not reported
UEI
Not reported
Solicitation number
Not reported
Topic code
Not reported

Research abstract

This Small Business Innovation Research Phase I project will develop a method to lower the practical quantitation level of arsenic using a novel instrumental improvement to existing Inductively Coupled Plasma - Mass Spectrometry (ICP-MS) and Atomic Emission Spectrometry (AES) techniques. by replacing the standard sample introduction nebulizer and spray chamber used in ICP-MS and ICP-AES with the Nanomiser. device and thus lower the detection limit of arsenic and other elements. The Nanomiser enables very fine atomization of solvent/analyte mixtures with exceptional control over size, while maintaining a narrow size distribution. Results to date show that this breakthrough technology leads to the generation of a monodisperse aerosol with a mean diameter in the sub-micron to micron-range. Furthermore, this technology provides high residence time (due to low and independently controlled carrier gas velocity), which is, together with the small particle size, one of the main requirements for adequate thermal evaporation and dissociation of aerosol particles. The independence of gas flow and atomization will help to significantly increase the ionization of elements with higher first ionization energies, such as arsenic, by allowing for longer residence time in the plasma. The development of a reliable sample introduction technology can significantly improve the detection limits of conventional systems for atomic spectroscopy. Furthermore, the small size and compact design of the Nanomiser device will allow this technology to be easily retrofitted into existing AES and MS systems in collaboration with major instrument manufacturers.

Technology keywords

Not reported

Agency intelligence

National Science Foundation

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.