SBIR/STTR Research Award

Reducing Infection in Indwelling Medical Devices

Award identifier 04adb4e308b3121d0f86a79a1359740375c8178db9c402ef673669b81ce625ddAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$115,294

Program and phase

SBIR · Phase I

Award year

2001

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
AST PRODUCTS, INC.
Proposal award date
Not reported
Contract end date
Not reported
UEI
Not reported
Solicitation number
Not reported
Topic code
Not reported

Research abstract

DESCRIPTION (Verbatim from the Applicant's Abstract): Urethral catheters are essential in the management of many diseases and conditions yet often result in catheter associated urinary tract infections. The use of sterile closed systems, advanced infection control protocols, and antimicrobial parts has not prevented infection or the associated morbidity increase. Additionally, direct patient care costs for these infections exceed $0.5billion annually. Our novel ironically bonded antimicrobial coating shows promise for the long-term prevention of infection in urethral catheters. This research will establish that unlike conventional systems where the antimicrobial agent is entrapped in a matrix and acts through diffusion, our antimicrobial agents are ionically bonded to a polymeric backbone. The release mechanism is one of ion exchange and is not purely diffusional. The effectiveness is thus sustainable for a long period. Initial work will establish antimicrobial activity as a function of time against four organisms characteristic of nosocomial urinary tract infections. The method of release will be established by comparing the results of three different measures of antimicrobial activity, namely, the zone of inhibition and bacterial adherence tests. Preliminary biocompatibility tests and coating integrity will be conducted as well. Coating effectiveness greater than 1 week will justify further in vivo investigations. PROPOSED COMMERCIAL APPLICATION: Urethral catheters that effectively reduce the incidence of infection in long-term use have great market potential due to the reduction in mortality, morbidity, and direct patient costs. For instance, the direct patient costs associated with the treatment of catheter associated urinary tract infections exceeds $0.5 billion annually. The success of Bard's hydrogel/silver Foley catheter demonstrates that the medical and insurance communities would be highly receptive to reasonably priced products that significantly reduces the incidence of nosocomial urinary tract infections. While advances in infection control procedures and medical devices have reduced the overall incidence of catheter associated urinary tract infections, in long term (> one week) catheterizations there is a greater than 50% chance that those patients will acquire a sometimes anti-biotic resistant infection. There are no products that are effective for more than 1 week. Preliminary results have shown that our antimicrobial coating is effective for as long as 30 days, a four-fold increase over any other commercially available product. Since our coating does not alter the physical characteristics of the base material or product, acceptance by the medical device community once safety and efficacy is established should be achievable with appropriate business development efforts.

Technology keywords

Not reported

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.