SBIR/STTR Research Award

Next Generation Neutron Diffraction Detector for Neuroscience

Award identifier 1b8d59cca319dc50910adcc28bc760ed4d3f80cbc4acfd3913f87950f68862ebAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$152,301

Program and phase

SBIR · Phase I

Award year

2012

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
NOVA SCIENTIFIC INCORPORATED
Proposal award date
Not reported
Contract end date
Not reported
UEI
XZHZG8FM18S3
Solicitation number
PA11-096
Topic code
NIGMS

Research abstract

DESCRIPTION (provided by applicant): NOVA Scientific proposes to adapt a powerful new type of neutron diffraction instrumentation for biological applications, a neutron counting and imaging detector called the MCP/Medipix detector. The detector offers muchhigher spatial and timing resolution, as well as higher count rate capability (10-100 MHz) and dynamic range compared with existing neutron position-sensitive detectors. It was designed to provide state-of-the-art performance to match the higher neutron fluences of next generation of neutron scattering and imaging facilities. Although demonstrated successfully during the past year in other applications, this powerful new instrument has never been applied to research in cellular and structural biology. We propose for the first time to modify and employ it as new detector tool to elucidate biologically important structures by using it in neutron diffraction (ND). One highly promising biological system which could benefit would be myelin, the electrically insulating material that ensheathes the neuron axon; its integrity is critically important for the proper functioning of the nervous system. Myelin ultrastructure studies, traditionally carried out using electron microscopy and X-ray diffraction could be substantially enhanced by using a more powerful new type of neutron diffraction (ND) detector, particularly with the increasing availability of a variety of transgenic mice that model human demyelinating disorders. Myelin would be an ideal test case for demonstrating the MCP/Medipix detector, as it allows benchmarking of previous ND measurements carried out with 3He detectors. This will demonstrate that that the improved performance of the MCP/Medipix detector represents a major advance in the power of ND forcellular and structural biology. In Phase I neutron diffraction experiments will be carried out using mouse nerves for the first time anywhere, as there are numerous transgenic mice strains that mimic human myelinopathies in both the PNS and CNS. To accomplish this, assembly and integration of a neutron sensitive 40 mm MCP with a modified Medipix readout will be carried out, preparing it for high fluence neutron diffraction experiments on a biologically-oriented neutron diffractometer. Also a versatile andadvanced perfusion cell will be constructed allowing deuteration of samples for enhanced contrast variation, and to minimize neutron scattering noise. Two ND diffraction test campaigns will be carried out with the MCP/Medipix detector. Different aspects of myelin ultrastructure will be illuminated to show feasibility of ND as an essential tool for answering specific questions about myelin structure and inter-membrane dynamics. A Phase II program would expand this initial feasibility study to build largerarea format MCP/Medipix detectors with the addition of advanced neutron beam collimation, to obtain even greater neutron sensitivity and diffraction pattern resolution, as well as data collection speed and efficiency. Ultimately, the MCP/Medipix detector and collimator ND enhancement would be commercialized for the benefit of the biological ND community. PUBLIC HEALTH RELEVANCE: This project develops new laboratory instrumentation to increase the power of neutron diffraction (ND), a highly sophisticated technique with the potential to probe far deeper into the actual structure of myelin, the electrically insulating material that ensheathes central core of nerve fibers. The integrity of myelin is critically important for the proper functioning of thenervous system; demyelinating disorders such as multiple sclerosis (MS), certain peripheral neuropathies, and leukodystrophies are characterized by the progressive disruption and breakdown with partial or attempted re-formation of the highly ordered myelin sheath. The ability to accurately measure these extremely subtle features of myelin, enabled by the new NOVA Scientific/Medipix detector, will increase our knowledge about disease states, and will help to provide insight into developing therapeutic strategies for stabilizing normal myelin or remyelinating nerve fibers.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

40 SBIR/STTR records share this UEI (1993–2019). Reported award amounts total $12,777,155. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Energy, Department of Defense, Department of Health and Human Services, Department of Commerce, Department of Homeland Security, National Science Foundation

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.