SBIR/STTR Research Award

A Portable Gamma Spectrometer with a High Resolution CdTe Array Detector

Award identifier fb31b6eafe695fcbb7588dcbc1dfba209fdf6b6548b8b95416f379c7cc3ab3bfAwarding agency Department of Defense · Defense Threat Reduction Agency

Award amount

$749,887

Program and phase

SBIR · Phase II

Award year

1997

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Defense
Branch
Defense Threat Reduction Agency
Recipient company
Radiation Safety Engineering, Inc.
Proposal award date
Not reported
Contract end date
Not reported
UEI
XMWCMYLMH8N7
Solicitation number
Not reported
Topic code
Not reported

Research abstract

We propose to develop a battery powered portable monitoring system capable of collecting and analyzing gamma spectra for specific radionuclides in the field. The system will consist of a high resolution cadmium telluride array detector and a small multichannel analyzer and data logger. The proposed monitoring system builds upon the design of the Ludlum Model 2350 Data Logger which is quite rugged and can operate for extended periods of time on battery power. The data logger will be reconfigured as a small multichannel analyzer that will integrate under specific regions of interest and report results by isotope on a large LCD display. For large projects the instrument will have the capability of dumping its data to a notebook computer. The detector will consist of spectroscopy grade CdTe crystals in an array, with individual preamplifiers to preserve the detector resolution. The detector array should have a resolution of 5 - 7 KeV at a photopeak energy of 60 KeV which is sufficient to identify most nuclides, and is particularly effective for the low energy photopeaks associated with transuranic radionuclides. The CdTe detector operates at room temperature and does not require cooling. The research should lead to the development of a small, rugged gamma spectrometer capable of rapid isotope identification. The instrument should be suitable for safeguards and other field applications. As you know, AM has been operating under a beta-test of the new network-based/Windows-based AM Tracking System since 13 May 1994. The beta-test has allowed us to develop knowledge of and confidence in the new system while maintaining a a backup in the original PR Tracking. In keeping with the original implementation plan, the beta-test is now declared completed and maintenance of the original PR Tracking system will be discontinued immediately. Negotiators are no longer required to submit hard-copy corrections using the Tracking printouts. Updates are to be made to individual actions in real time, at a minimum on a daily basis.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Research funding history

8 SBIR/STTR records share this UEI (1993–2001). Reported award amounts total $1,412,249. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Nuclear Regulatory Commission, Department of Defense, Department of Energy

Agency intelligence

Department of Defense

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.