SBIR/STTR Research Award

Optimization of Catheter Antennas for Intravascular MR

Award identifier be17d2ce13e574b2a242b2ad1e35cc3c9ccdd4f2d4ee49ace0c6e66467e713b8Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$266,006

Program and phase

STTR · Phase I

Award year

2005

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
INTERVENTIONAL IMAGING, INC.
Proposal award date
Not reported
Contract end date
Not reported
UEI
Not reported
Solicitation number
Not reported
Topic code
Not reported

Research abstract

DESCRIPTION (provided by applicant): This proposal intends to optimize catheter-based micro radio frequency antennas used in MR-guided, intravascular interventions for high resolution imaging of the arterial wall. A resolution of approximately 200 microns is needed to depict atherosclerotic plaque components in a diseased vessel wall. RF antennas must provide a high signal-to-noise ratio (SNR) to keep acquisition time (TA) short during interventions. Our previous work showed that simple changes in coil winding patterns can double SNR and reduce TA by 4. Thus, we focus on an in-depth optimization of catheter-coils with respect to their SNR. For this purpose, an extensive computer simulation program will be developed which calculates 3D-SNR maps as a function of the antenna geometry and orientation relative to BO. In order to find the best antenna design for a given application, this software will be specifically used to: 1) perform a formal comparison of common intravascular coils (e.g. loop vs. opposed solenoid coil), and 2) investigate possible improvements in SNR by changing geometry through hybrid combination of multiple designs (e.g. by adding loops to an opposed solenoid coil). Design changes necessitate recalculation of the SNR map. When comparing different coils, the best design will be chosen based on the highest SNR calculated at the anticipated location of the wall in a cross-sectional slice through vessel and center of the coil. We will restrict our optimization to coils for coronary and renal artery imaging and construct potentially useful designs identified by simulations using surface mount or micro fabrication technology. All assembled devices will be tested in MR phantom imaging. SNR maps will be acquired at multiple orientations. Measured SNR maps will be compared with simulation data and simulation accuracy for all coils manufactured will be evaluated. Finally, the best designs will be tested in vivo in a porcine animal model. We anticipate that this project will lead to identification and prototyping of SNR-optimized catheter coils for further testing in animal models of vascular disease in Phase II.

Technology keywords

Not reported

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.