SBIR/STTR Research Award

Measuring Endoscopic Probe - A Novel Supportive Tool for Endoscopy

Award identifier b513f4ed22d52015d45fc60be014302265656c4539802b92dd516aa7503d6a89Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$138,995

Program and phase

SBIR · Phase I

Award year

2010

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
INTELLIGENT OPTICAL SYSTEMS, INC.
Proposal award date
Not reported
Contract end date
Not reported
UEI
NLDHG92SMX37
Solicitation number
PHS2010-2
Topic code
NCRR

Research abstract

DESCRIPTION (provided by applicant): Noncontact remote dimensional measurements in difficult to access areas are an important part of nondestructive remote visual evaluation in many industrial fields. Endoscopes are the major devices that are used for this purpose. It is impossible, however, to measure the actual size of the imaged objects using an endoscope that is not equipped with additional features, as the instrument magnifies object details depending on its distance from the endoscope tip, and this distance is unknown, and is constantly changing during the examination. This measurement situation changed, in 1996, when Olympus Industrial introduced a two objective measuring endoscope that produced an optical stereopair that could be used to determine distance via the triangulation method used in classical two-camera photogrammetry. The diameter of the outer shaft of this endoscope is 4.4mm, and the device is widely used in the industrial field. The medical community, however, has not embraced this device, most likely for two reasons: (i) a reduced angle of view (700) compared to the larger angle of view (more than1100) used in endoscopic visual examination; and (ii) the high cost involved in the measurement process. Diagnostic endoscopy is typically qualitative. The physicians make conclusions from observation of the tissue colors and abnormalities. High quality color reproduction devices with a wide field of view are in use. As medical diagnostics progresses, however, there are more requests for quantative measurements during endoscopy. The development of an endoscopic supportive tool with measurement capabilities, that will not interrupt the endoscopic procedure, but can rapidly provide quantative support to the diagnosis, would be valuable to medical practitioners. This tool would best be delivered through the instrumental channel of the endoscope, as are other supportive tools. The diameter of the instrumental channel is restricted, however, and a two lens probe, such as the Olympus probe, will not fit in the channel. Intelligent Optical Systems (IOS) is collaborating with the UCLA Medical Center and School of Engineering to develop technologies specifically focused on the fabrication of novel unique surgical tools and MEMS devices to enhance endoscope measurement capabilities. IOS has developed and proven a method of producing a stereopair using a single lens with an optically transparent tilting plate in front of the lens. UCLA researchers have fabricated and demonstrated the operability of a MEMS device incorporating an optically transparent plate. In this project, the IOS-UCLA team proposes to develop a single lens endoscopic measuring probe no more than 2.5mm in diameter. In Phase I, the team will fabricate and demonstrate a measuring endoscope probe prototype 5.5mm in diameter, based on an already fabricated tilting plate; develop measurement algorithms and software, and modify the MEMS fabrication flow process to downsize the device to the 2.5mm dimension. A precommercial prototype of the measuring endoscopic probe, ready for FDA approval, will be presented at the end of Phase II. PUBLIC HEALTH RELEVANCE: Requirements for quantifying the size of lesions, polyps, and other pathological parts of tissue during endoscopy diagnostics, are growing. Reliable, low cost, high accuracy tools to support endoscopy procedures with quantative data, however, do not exist. IOS, in collaboration with UCLA researchers, proposes to develop a measuring endoscopic probe, a tool that can be inserted into the instrumental channel of the endoscope, and will provide dimensional measurements of biological objects during endoscopic procedures. This novel tool will help to reduce the number of uncertainties that still exist in endoscopy diagnosis.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

264 SBIR/STTR records share this UEI (1998–2025). Reported award amounts total $77,140,779. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Defense, Department of Health and Human Services, National Aeronautics and Space Administration, Department of Energy, Environmental Protection Agency, Department of Agriculture

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.