SBIR/STTR Research Award

Sonomicrometry System for Rotary Blood Pump Control

Award identifier f732d1be4ec64516212d49c74d25e89a2b0ba5acfa977b9295c6788635827ac9Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$656,719

Program and phase

SBIR · Phase II

Award year

2003

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
VASCOR, INC.
Proposal award date
Not reported
Contract end date
Not reported
UEI
Not reported
Solicitation number
Not reported
Topic code
Not reported

Research abstract

DESCRIPTION (provided by applicant): Design and qualification testing of an automatic, closed-loop control system for implanted rotary blood pumps is proposed The control system is expected to significantly improve the efficacy and safety of treating Congestive Heart Failure patients with rotary blood pumps by eliminating problems associated with rotary pumps such as ventricular collapse caused by over-pumping and inadequate perfusion caused by under-pumping Three sonomicrometry transducers are permanently implanted within the wall of the left ventricle A software-based controller uses the sensed inter-transducer distances to optimally control the speed of a rotary pump to avoid excessive distension or contraction of the ventricle Specific aims of the project are to 1) Design and evaluate a clinical sonomicrometry lead suitable for human use -A formal specification will be prepared, leads and installation tools will be designed, prototypes will be fabricated, and in vitro and in vivo tests will be performed 2) Design and evaluate transducer interface circuitry capable of being sufficiently miniaturized for human implant - A formal specification will be prepared, circuitry will be designed, prototypes will be fabricated, and in vitro and in vivo tests will be performed 3) Develop and evaluate a closed loop pump control algorithm - A formal specification will be prepared, the algorithm will be developed, the algorithm will be evaluated using a computer model of the human circulatory system, and in vitro and in vivo tests will be performed 4) Fabricate and qualify sonomicrometry leads for human use - Production procedures will be prepared, a pilot production line will be setup, production processes will be validated, leads will be fabricated, and in vitro and in vivo qualification tests will be performed .

Technology keywords

Not reported

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.