SBIR/STTR Research Award

Non-contact membrane probe

Award identifier 8b5f2c093668e87706e19118539eff3d8bbea75c1abc976f65e4340ee774c792Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$1,200,000

Program and phase

SBIR · Phase II

Award year

2005

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
Prairie Technologies, Inc.
Proposal award date
Not reported
Contract end date
Not reported
UEI
Not reported
Solicitation number
PHS2005-2
Topic code
Not reported

Research abstract

DESCRIPTION (provided by applicant): Reading the conformational state of membrane proteins is central to understanding their role ir cell signaling, to using them as sensor elements and for screening candidate drug compounds that are targeted toward this important class of biomolecules. While the patch clamp technique for doing this is ubiquitous, it does have significant limitations: two electrodes are required to measure current flow, the gigaohm input impedance combines with unavoidable stray capacitance to limit the amplifier's bandwidth (typically to -10 kHz), and the gigaohmseal required at the cell membrane precludes scanning to image both distribution and dynamics of membrane proteins. To address these limitations, we will develop near-field probes, readouts, positioners and software to make a prototype system that confines high-frequency excitation to sub-wavelength proportions, enabling interaction with single membrane proteins. Since there are inherent dielectric contrast mechanisms available in protem-lipid systems, these can be used at high frequencies to provide a new method of protein readout. We have succeeded in demonstrating simultaneous recordings from alpha-hemolysin blocked by beta-cyclodextrin using both a conventional patch-clamp amplifier and a microwave source and detector. The microwave probe has the advantage of approximately 1 MHz bandwidth, so it is able to resolve more temporal detail than the patch clamp. Furthermore, the microwave probe is sensitive to changes both in conductance and capacitance, i.e. the movement of charge groups in the channel. This opens the door to probing for the first time changes in conformation that do rot otherwise change channel conductance. Finally, the microwave probe by its nature does not require a gigaohm seal (in fact, its impedance is 50 ohms), enabling us to realize a scanning electrode that can map both distribution and dynamics of channel activity. We will develop this prototype in conjunction with a collaborator in neuroscience so that the feedback gained from a field test will be used in making the system commercially viable.

Technology keywords

Not reported

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.