SBIR/STTR Research Award

Fast Measurement of Adult Body Volume in Air

Award identifier 21c22f38b2f998f883b7a65bb498aca9c62f1c9700225f130b3e5c62ccb6582fAwarding agency Department of Health and Human Services

Award amount

$497,392

Program and phase

SBIR · Phase II

Award year

1995

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
Not reported
Recipient company
Hydronautics Research, Inc.
Proposal award date
Not reported
Contract end date
Not reported
UEI
Not reported
Solicitation number
Not reported
Topic code
Not reported

Research abstract

We will develop an inexpensive device that rapidly measures the body density (in air) of non-infant children and adults, so a quantitative degree of obesity (body fat fraction) may be deduced. Such routine measurements should result in improved weight control programs with consequent reduction in the health risks associated with hypertension, cardio vascular disease, cancer, diabetes, and many other disorders. There are two known methods that have been proposed for the in-air measurement of body volume¿principally for infants. One is based on air displacement and the intrinsic relationship between gas volume and pressure. Another method, using the Helmholtz resonator principal with excitation from a loud-speaker, has also been proposed for infants. Both methods are complex and highly sensitive to temperature. The new device also uses acoustic resonance principles, but eliminates problems related to temperature or humidity changes. It is expected that very accurate measurements can be made in much less than a minute with readout in body density and estimated percent body fat. The device should be inexpensive and a product desired and eventually required by most physicians. Specific aims of Phase I would include design and construction of a breadboard acoustic volume device to measure the volume of adults and optimize the system by measuring a range of known volumes of water. Some preliminary studies would also be conducted with some human volunteers.

Technology keywords

Not reported

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.