SBIR/STTR Research Award

Arterial Cannula with Permissive Distal Perfusion

Award identifier 50983c5faca38a0ab995550b5116d24852d8b43b3e98fa21ddeccae08c88de3fAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$427,762

Program and phase

SBIR · Phase II

Award year

2007

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
MICHIGAN CRITICAL CARE CONSULTANTS, INC.
Proposal award date
Not reported
Contract end date
Not reported
UEI
NVSPCRHNAF11
Solicitation number
Not reported
Topic code
Not reported

Research abstract

DESCRIPTION (provided by applicant): A novel cannula design is proposed to provide distal perfusion during arterial cannulation. Arterial cannulation is common in several applications of extracorporeal blood processing, such as ArterioVenous Carbon Dioxide Removal (AVCO2R) treatment. AVCO2R is a respiratory treatment that uncouples oxygenation from CO2 removal by utilizing a low-resistance gas exchanger in a simple percutaneous arteriovenous shunt (i.e. pumpless) to achieve near-total extracorporeal removal of CO2 production. As in all extracorporeal applications that require arterial cannulation, complications such as infection and distal ischemia can occur. A unique distal perfusion cannula (DPC) is presented, where a 3-section balloon incorporated at the tip of the cannula acts as a vessel support, as well as a variable flow controller that ensures and regulates distal flow. This design approach allows for the cannula size to be maximized, which minimizes the resistance of the extracorporeal circuit, while ensuring safety for the patient. The DPC described here offers a simple, adjustable solution to femoral cannulation and will hold the key to the adoption and efficacy of AVCO2R, as well as other extracorporeal support therapies. In Phase I, computational techniques and in vitro experiments were used to design the distal perfusion cannula (DPC), and to fully characterize the prototypes. A functional, 3-section balloon prototype has been completed and verified of its ability to optimize both distal and cannula perfusion. The objective of Phase II is to construct a clinical quality DPC, and to verify that the cannula is successful in optimizing distal flow while minimizing complications on an in vivo animal model. At Phase II conclusion, manufacturability of the DPC will be defined, and the long-term functionality of the device will be determined. This grant will result in the development of a novel distal perfusion cannula (DPC) for use in arterial cannulation. The new DPC will optimize the performance of an extracorporeal circuit, while ensuring safety for the patient.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Research funding history

68 SBIR/STTR records share this UEI (1991–2023). Reported award amounts total $29,918,691. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Health and Human Services, Department of Defense

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.