THERAPEUTIC CORRECTION OF ASTIGMATISM WITH EXCIMER PRK

Award identifier 5db3bd2874cc286fe80ed23406b09cc520de2be5c5f4e00668a06f333165d58dAwarding agency Department of Health and Human Services

Award amount

$500,000

Program and phase

SBIR · Phase II

Award year

1993

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
Not reported
Recipient company
Visx, Inc.
Proposal award date
Not reported
Contract end date
Not reported
UEI
Not reported
Solicitation number
Not reported
Topic code
Not reported

Research abstract

WE INTEND TO GENERATE PRESCRIBED NEGATIVE CYLINDER EXCIMER LASER ABLATIONS USING TECHNOLOGY ANALOGOUS TO THAT PRESENTLY BEING USED FOR THE CORRECTION OF MYOPIA IN HUMAN CLINICAL TRIALS. THE DEVICE WOULD CORRECT HIGH AMOUNTS OF ASTIGMATISM FOR WHICH TREATMENT WITH GLASSES AND CONTACT LENSES IS PROBLEMATIC BECAUSE OF INDUCED BINOCULAR VISION PROBLEMS DUE TO POOR LENS ORIENTATION. A PROTOTYPE DEVICE FOR GENERATING PRESCRIBED CYLINDRICAL ABLATIONS WILL BE DEVELOPED AND EVALUATED ON PMMA TEST SURFACES TO TEST FOR THE ACCURACY AND RELIABILITY OF SYSTEM FUNCTION. ALIGNMENT TECHNIQUES, WHICH PROVIDE FOR AXIS ORIENTATION AND ABLATION CENTERING, WILL ALSO BE EVALUATED. A PROTOTYPE INSTRUMENT IS PRESENTLY BEING DEVELOPED AND SHOULD BE OPERATIONAL BY THE TIME OF FUNDING. THE DEVICE WILL PROVIDE FOR MERIDIONAL ADJUSTMENT OF 1/3 DEGREE INTERVALS, SLIT WIDTH ADJUSTMENT WITHIN 9 U PER STEP AND PRECISE RATE OF CLOSURE. THE DESIGN IN INTENDED TO EXCEED THE EXPECTED AND PATIENT ABLATION TOLERANCES OF + 0.25 D AND + 2.0 DEGREES. PMMA TESTING WILL BE CARRIED OUT ON TWO TYPES OF SURFACES, FLAT SAMPLES AND SPHERICAL CONTACT LENSES. FOR THE SAMPLES HAVING CYLINDRICAL COMPONENT, THE POWER OF THE PRESCRIBED ABLATION CYLINDER WILL BE EQUAL TO THE COMPLEMENT OF THE SAMPLE CYLINDER. THUS, REDUCTION OF THE CYLINDRICAL COMPONENT TO ZERO WOULD PROVIDE VERIFICATION OF THE ABLATION MODEL, AND RESIDUAL CYLINDER WOULD INDICATE AN ERROR IN THE ABLATION ALGORITHM, HARDWARE, OR ALIGNMENT PROCEDURES. FOR CLINICAL APPLICATION EYE ALIGNMENT PROCEDURES WILL BE DEVELOPED DURING THAT LATTER PHASES OF THE PROJECT. THIS WORK WILL BE CARRIED OUT IN PARALLEL WITH THE OTHER STUDIES.

Technology keywords

Not reported

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.