SBIR/STTR Research Award

ULTRASONIC BLOOD VISCOMETER

Award identifier eedada26f21502f44baa46c0f80a4ffa61f4939a0901b86cceda1d50bef67461Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$91,703

Program and phase

STTR · Phase I

Award year

2001

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
INDUS INSTRUMENTS
Proposal award date
Not reported
Contract end date
Not reported
UEI
QXR4S6FM82R8
Solicitation number
Not reported
Topic code
Not reported

Research abstract

DESCRIPTION (Verbatim from Applicant's Abstract): Blood viscosity is altered in diseases such as sickle cell anemia, hypertension, and atherosclerosis and also during coagulation, but its measurement requires complex and expensive instrumentation and is thus rarely done. We propose to develop an ultrasonic technique to simplify this measurement using small samples of blood. An ultrasound beam produces streaming in fluids, and a pulsed Doppler velocimeter can be used to both induce and measure the streaming velocity which is determined by both the acoustic and physical properties of the fluid. In addition, the time constant to a step change in acoustic power is also a function of viscosity and density. We propose during Phase I to develop a 20 MHz pulsed Doppler and signal processing to show: 1) that streaming can be measured in 50 mu1 of canine or murine blood with a 1 mm transducer; 2) that the streaming velocity and time constant are functions of viscosity; and 3) that streaming is reproducible and stable. During Phase II we will model the streaming process using finite difference methods, and based on the results will design an instrument and apparatus optimized for measuring viscosity in small samples of freshly drawn whole blood. This technique could also become the basis of a whole-blood coagulation detector and timer and could be incorporated into a laboratory analyzer. In research it will be used to study hemorheology in genetically altered mice. PROPOSED COMMERCIAL APPLICATION: The testing of blood is a major activity in hospital laboratories, and the concepts to be developed here could be incorporated into the measurement of coagulation timing and viscosity. The measurement of blood viscosity at the bedside for diagnosis and for monitoring of therapeutic manipulations is essentially a new market where the implications could be very great.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Research funding history

9 SBIR/STTR records share this UEI (1994–2018). Reported award amounts total $2,978,675. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Health and Human Services

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.