SBIR/STTR Research Award

BLADDER FUNCTION MONITORING SYSTEM

Award identifier d710475a2b1cb29e4cac5449f02491ac5df45912b31af5cbdcfc8ec969b223b8Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$100,000

Program and phase

SBIR · Phase I

Award year

2005

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
Dynaventions, Inc.
Proposal award date
Not reported
Contract end date
Not reported
UEI
Not reported
Solicitation number
PHS2005-2
Topic code
Not reported

Research abstract

DESCRIPTION (provided by applicant): Urinary incontinence is a common and debilitating problem for more than 40 million people worldwide. The current gold standard method of diagnosing incontinence involves cystometry and urodynamics: expensive, nonphysiological laboratory tests that do not always reproduce patient complaints. We are proposing feasibility testing of a bladder function monitoring system, the DynaSystem(tm), which will monitor bladder function continuously for up to 48 hours with the patient unencumbered by external catheters, much as a holler monitor does for the heart. The DynaSystem will consist of a control unit connected wirelessly to 2 probes, an intravesical one [the DynaSphere] and an intravaginal one [the DynaPessary(tm)]. The DynaSphere will monitor bladder pressure and volume, as well as urine temperature, conductivity, and pH. It will be based on technology developed for the ContiSphere(tm), a balloon continence device that is inserted intraurethrally and inflated with low density mineral oil using an insertion device. The insertion device is then removed and the balloon will float in the bladder without obstructing voiding. The DynaPessary will wirelessly monitor abdominal pressure as well as patient position and movement using an inclinometer and accelerometers. The balloon carrier is presently undergoing clinical testing and miniaturized transducers are available for all variables to be recorded, except for bladder volume. Therefore, in this Phase I feasibility testing proposal we concentrate on development and testing of an intravesical bladder volume sensor using an electrical conductance technique whose potential is demonstrated in pilot data. The work will be accomplished by the following Specific Aims: Specific Aim 1: Determine the combination of design parameters that best achieves acceptable accuracy and reproducibility of volume sensing using the conductance technique. Specific Aim 2: Perform sensitivity analysis on the volume measurements to determine sensitivity to changes in bladder and urine. Specific Aim 3: Prototype and test foldable models based on the best performing rigid probes. Device development will be performed at Dynaventions, Inc. Testing of the prototypes will be performed at Hines VA Hospital using bladders from pigs already being used in lACUC-approved studies. When bladder volume can be measured intravesically to acceptable standards using a foldable probe, we will be ready for Phase II development and testing.

Technology keywords

Not reported

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.