SBIR/STTR Research Award

Ultrasound Exposimetry Using Liquid Crystal Plates

Award identifier 4ba3160f8896eceb150b71d51b620864c7e171dc9ec9c306c9fabc9e5e7f1d8aAwarding agency Department of Health and Human Services

Award amount

$49,950

Program and phase

SBIR · Phase I

Award year

1993

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
Not reported
Recipient company
SANTEC SYSTEMS INC
Proposal award date
Not reported
Contract end date
Not reported
UEI
NLEJLJFMPLL3
Solicitation number
Not reported
Topic code
Not reported

Research abstract

Liquid crystal-based sonosensitive plates will be investigated for rapid determination of spatial distributions of temporal average intensities for diagnostic ultrasound beams, including real-time imaging and Doppler modes. From such distributions, exposure parameters such as SPTA (spatial peak-temporal average) and SATA (spatial average-temporal average) can be determined. In this approach, ultrasonic field is visualized directly on the plate as the liquid crystal molecules are reoriented by the ultrasonic field from their initial unidirectional orientation. Then, an electric field is applied to restore the orientation of the molecules. The magnitude of the restoring electric field is then used to determine the sonographic exposure parameters. The approach offers several advantages over presently used hydrophone and radiation force balance methods. For example, image of the cross-sectional field distribution is available at once. Moreover, the distribution of temporal average intensity over the plane perpendicular to the propagation axis is available at once from the electric field data. In comparison, the hydrophone method is cumbersome as point-by-point detection of a large number of sample points is needed to determine field distribution. The radiation force balance method, on the other hand, requires an elaborate set-up and provides no information on the spatial distribution of the ultrasonic field.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Research funding history

18 SBIR/STTR records share this UEI (1990–2016). Reported award amounts total $4,225,393. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Defense, Department of Health and Human Services, National Science Foundation

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.