SBIR/STTR Research Award

Rapid, Low-Cost System for Detection of Bacterial Contamination of Blood Pla--OLD

Award identifier 945346668a9ad3f125a6c4dc750b1304419867bbd01890c8e47d8e36f1d8d38eAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$109,552

Program and phase

SBIR · Phase I

Award year

2009

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
SOFTRAY, INC.
Proposal award date
Not reported
Contract end date
Not reported
UEI
Not reported
Solicitation number
PHS2009-2
Topic code
Not reported

Research abstract

DESCRIPTION (provided by applicant): This STTR Phase I project will prove the concept for a low-cost, rapid system for detecting bacterial contamination in platelet concentrates, in minutes and not days, with cost/performance equal to accepted testing methodologies. Though the US has one of the safest blood supplies in the world, significant danger exists from the transfusion of blood products contaminated with pathogenic bacteria. Bacterial infection represents the most dangerous transfusion-related risk in the US other than human error. Blood banks incubate platelet cultures for 2 days for bacterial testing. Since platelet units have a shelf life of 5 days, this 2- day reduction in shelf life has a harsh impact on the supply. The proposed solution will extend platelet lifetime by more than 30%, as well as enable the release of fresher platelets, which are safer and more effective than older platelets. The objective of this proposed RandD effort is to build and test a proof-of-concept system and develop a staining method for the detection of bacteria in platelet concentrate units. The proposed proprietary method is called Fountain Flow Cytometry. This method is based on a system in which a stream of solution containing the microorganisms, labeled with fluorescent probes, is illuminated with an LED and the fluorescence is detected with a digital camera. The use of low-cost commercial digital cameras and LEDs makes this device economically attractive when compared to alternatives. The proposed research will test alternative dye combinations with a system designed to detect bacteria spiked into apheresis platelets against a background of red and white blood cells. The anticipated result is an alternative to more expensive, less sensitive, and slower detection systems. Fountain Flow will allow detection of platelet contamination at the sensitivity of automated culturing devices, but in ~10 minutes. The system can be automated and would potentially allow the examination of hundreds of platelet units per day. Tests will be performed on E. coli inoculated into human apheresis platelet units. Key performance criteria will be the method detection limit (MDL) for E. coli, total assay time, detection efficiency, and rate of false- positive detections. Our overall performance objectives to demonstrate commercial viability of the technique are an MDL of ~1 bacterium/ml (in a 10ml sample) with a detection efficiency gt75% (bacteria detected/bacteria present) and a flow rate of gt3.0 ml/minute. The key task in this project is to develop a combination of staining reagents that will achieve these objectives. This research will be performed by a team of scientists from SoftRay Inc. in colaboration with its University of Wyoming STTR partner, a transfusion medicine consultant (Bonfils Blood Center, Denver), and a clinical microbiologist (Cleveland Clinic). PUBLIC HEALTH RELEVANCE: Approximately four million units of platelet concentrates are transfused in the United States annually, with an estimated one in one thousand to one in three thousand units contaminated with potentially pathogenic bacteria. Blood contaminated by bacteria now represents the most dangerous transfusion related risk in the US other than human error. This project proposes a system that will provide for lower-cost, more timely and more sensitive detection of bacterial contamination, providing for a safer blood platelet supply for transfusion.

Technology keywords

Not reported

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.