SBIR/STTR Research Award

Improving Host Response to Implantable Glucose Sensors via Nitric Oxide Release

Award identifier ea6f9a37fe3707dee0df3e791188804e10b80d02fb560370560acb375fabd60cAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$995,855

Program and phase

SBIR · Phase I

Award year

2011

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
Novan, Inc.
Proposal award date
Not reported
Contract end date
Not reported
UEI
JVY7LPMCSFM8
Solicitation number
DK10-008
Topic code
NIDDK

Research abstract

DESCRIPTION (provided by applicant): Approximately 24 million adults and children in the United States have 1 Diabetes Mellitus (diabetes) and 1.6 million new cases are diagnosed each year. Type 2 is the most common form of the disease accounting for over90% of the diabetics worldwide. The remaining 5 to 10% of diabetics are plagued with the more serious Type 1 condition which is most often diagnosed in children, adolescents or young adults and is characterized by the body's inability to produce insulin. Type 1 diabetics living with this disease must frequently monitor their blood glucose levels to prevent deleterious bouts of hyper- or hypoglycemia. The 2010 American Diabetes Association guidelines recommend testing three or more times a day which resultsin a minimum of 1,095 finger sticks per year. Because of the cost, pain, and inconvenience of needle sticks, many diabetics do not follow the rigorous monitoring schedule necessary for maintaining healthy blood glucose levels. Continuous glucose monitoringsystems provide an alternative, real-time method for metabolic control. However, the reliability and resulting clinical utility of continuous glucose monitors is limited due the body's adverse response to subcutaneous implants. Current scientific knowledge regarding nitric oxide's role in reducing inflammation, preventing scar tissue formation, and increasing new blood vessel formation suggests that nitric oxide-releasing surfaces may create an optimal tissue environment to improve the accuracy of continuous glucose monitors. The purpose of this project is to create a nitric oxide-releasing device coating, using Novan's proprietary nitric oxide-releasing nanoparticle technology (Nitricil(tm)), to reduce the foreign body response that occurs upon implantation of subcutaneous glucose sensors. Through this two year, Phase I SBIR the Company aims to: 1) evaluate the foreign body response of Nitricil(tm) coated platinum wires in a rabbit animal model as a function of nitric oxide concentration and release kinetics; 2) fabricate four layer enzymatic glucose sensors using the optimized Nitricil(tm) coating from Aim 1 and evaluate sensor response using a lt 10% loss in sensitivity, response time, and/or linearity as pass/fail criteria; and 3) demonstrate the stability of both the nitric oxide-releasing coating and the enzyme-based sensor function on terminally sterilized sensors over time. Following the completion of Phase I milestones, Novan will explore the scale up of sensor dip-coating procedures, apply the coating to commercially available devices provided by a corporate partner, evaluate the biocompatibility of finished glucose sensors according to ISO-10993 and FDA guidelines, and conduct proof-of-concept testing of the Nitricil(tm)- coated glucose sensor in porcine animal models to establish mean absolute percent deviation from blood glucose levels. PUBLIC HEALTH RELEVANCE: Approximately 24 million Americans have Diabetes Mellitus (diabetes) at an annual economic cost of nearly 200 billion. Type 1 diabetics living with this disease must frequently monitor their blood glucose levels to prevent deleterious bouts of hyper- or hypoglycemia. Continuous glucose monitoring systems provide a real time method for metabolic control and have made significant stridestoward a closed-loop system. However, the reliability and resulting clinical utility of continuous glucose monitors is limited due the body's poor response to subcutaneous implants. The goal of this Phase I project is to create a nitric oxide-releasingdevice coating to reduce the foreign body response that occurs upon implantation of subcutaneous glucose sensors and improve the accuracy of these devices.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

12 SBIR/STTR records share this UEI (2008–2020). Reported award amounts total $7,994,402. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Health and Human Services, Department of Defense, National Science Foundation

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.