SBIR/STTR Research Award

High Rate Digital Signal Processing for Multi-Channel Microcalorimeters

Award identifier ef9baa116df67365de8752f9e5cbcaf71753ea5d4e67372c168a386c3864ba1eAwarding agency Department of Energy

Award amount

$750,000

Program and phase

SBIR · Phase II

Award year

2008

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Energy
Branch
Not reported
Recipient company
XIA LLC
Proposal award date
Not reported
Contract end date
Not reported
UEI
J26GQK3R6773
Solicitation number
DE-PS02-06ER06-30
Topic code
25

Research abstract

U.S. national laboratories are developing microcalorimeters as very precise detectors of electromagnetic radiation from near infrared to gamma ray frequencies, with much better energy resolution than existing detectors. Since microcalorimeters are small, they must be fabricated in large, 100-to-1000 channel arrays that, in turn, will require low-cost readout electronics with good energy resolution and high count rate capability. This project will extend the high precision digital readout electronics and digital filter algorithms, previously developed for germanium gamma-ray detectors, to very large microcalorimeter arrays. The objectives are to achieve (1) energy resolutions comparable to existing electronics, but with much higher count rates; (2) automated software for setup, calibration, and monitoring; and (3) a price of $100 per channel. In Phase I, microcalorimeter data was acquired from several research laboratories, and then processed offline and occasionally online. The resolution matched or exceeded the resolution from currently used ¿optimum¿ filters: ~0.07% resolution at low rates (versus 0.7-0.9% for optimum filters) and ~0.13% resolution at higher rates (versus 0.31%). The maximum theoretical count rate with good resolution was 155-1100 counts/s (versus ~ 8 counts/s). A preliminary design of a multi-channel prototype board was created that would meet the cost target. Phase II will complete the multi channel electronics design, build the hardware, and develop on-board firmware and software for multiplexed processing of slow microcalorimeter signals in high speed digital components. Commercial Applications and Other Benefits as described by the awardee: The proposed instrument should have applications in various scientific experiments employing arrays of microcalorimeters for X-ray or gamma-ray spectroscopy. A notable practical application is very precise isotope analysis of nuclear materials, which would make the instrument a valuable tool for nuclear non-proliferation. Similar instruments also could be used for quality control in semiconductor processing.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Research funding history

61 SBIR/STTR records share this UEI (1990–2025). Reported award amounts total $18,466,389. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Energy, Department of Health and Human Services, Department of Commerce

Agency intelligence

Department of Energy

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.