SBIR/STTR Research Award

USING ICP MASS SPECTROSCOPY WITH ELECTROTHERMAL ATOMIZATION

Award identifier 4736693f1924c13a913b6b8ae96089ac4ee8cb68f8cc2638dfd3d08d7fd35eecAwarding agency Department of Defense · Air Force

Award amount

$50,000

Program and phase

SBIR · Phase I

Award year

1986

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Defense
Branch
Air Force
Recipient company
Geochemical Services Inc
Proposal award date
Not reported
Contract end date
Not reported
UEI
Not reported
Solicitation number
Not reported
Topic code
Not reported

Research abstract

A NOVEL APPROACH TO SENSITIVE DIRECT ANALYSIS OF III-V COMPOUNDS AND OTHER SEMICONDUCTOR MATERIALS IS PROPOSED. FEASIBILITY DEPENDS ON THE SUCCESSFUL MODIFICATION OF HARDWARE AND SOFTWARE OF A COMMERCIALLY AVAILABLE INDUCTIVELY COUPLED PLASMA MASS SPECTROMETER (ICP/MS). FOR ROUTINE BULK ANALYSIS OF SEMICONDUCTOR SUBSTRATES, EPITAXIAL FILMS, DOPANTS, OR SOURCE MATERIALS, THE FOLLOWING CONCEPT IS PROPOSED. A SPECIALLY DESIGNED ELECTROTHERMAL ATOMIZER WOULD CONTAIN THE SOLID OR LIQUID SAMPLE AND CUSTOM SOFTWARE WOULD BE WRITTEN TO COLLECT ANALYTICAL DATA AS A FUNCTION OF THE THREE DIMENSIONS OF ION COUNTS, ATOMIC MASS, AND FURNANCE TEMPERATURE. BY THE PROPER CHOICE OF THE CARRIER GAS PASSING OVER THE SAMPLE, SEPARATION OF THE VARIOUS ELEMENTS CONTAINED IN THE SAMPLE SHOULD BE ACHIEVABLE IN THE THIRD DIMENSION OF TEMPERATURE. SPATIAL SEPARATION IN THE TEMPERATURE DIMENSION COULD BE USED TO ELIMINATE MANY MASS INTERFERENCE. DETECTION LIMITS FOR MOST ELEMENTS OF THE PERIODIC CHART ARE EXPECTED TO RANGE BETWEEN 0.01 AND 0.1 PPB. DEPTH PROFILES SHOULD BE ACHIEVABLE BY MASKING OFF THE AREA TO BE PROTECTED AND MOUNTING THE SAMPLE INSIDE THE ATOMIZER TUBE. THE CARRIER GAS WOULD THEN BE PASSED OVER THE SURFACE OF THE MOUNTED SAMPLE AT A TEMPERATURE SUFFICIENT TO ATOMIZE THE ELEMENTS OF INTEREST. THE TIME DIMENSION OF THIS THREE DIMENSIONAL DATA SET OF ION COUNTS, ATOMIC MASS, AND TIME COULD BE CALIBRATED TO DEPTH AND A PROFILE OF EACH ELEMENT AND ITS ISOTOPE RATIOS COULD BE CREATED WITH SUB-PPB SENSITIVITY.

Technology keywords

Not reported

Agency intelligence

Department of Defense

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.