SBIR/STTR Research Award

APD to Measure the Resistance of the Respiratory System

Award identifier 301d595875307a3824c4508acf9598311abad1c5e9e8213cf2503dc98338d94aAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$474,124

Program and phase

SBIR · Phase II

Award year

2007

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
ENGINEERING AND SCIENTIFIC RESEARCH ASSO
Proposal award date
Not reported
Contract end date
Not reported
UEI
H7NYR7CKS7A9
Solicitation number
Not reported
Topic code
Not reported

Research abstract

DESCRIPTION (provided by applicant): Respiratory screening and diagnosis are important in today's health care. Asthma and chronic obstructive pulmonary disease (COPD) constitute major health problems in the US. Mechanical ventilators are used increasingly for life support in patients with serious respiratory illness. Traditional pulmonary function tests (spirometry) are often not adequate to provide the respiratory functional information required by health care professionals. The Airflow Perturbation Device (APD) has undergone significant improvements over several years. APD is simple in concept, employing a rotating wheel in the flow path to change flow by 20-45%, with associated small changes in mouth pressure. From these changes, resistance is calculated. APD is simple in operation, requiring only normal breathing for one minute and is useful in children as well as adults. APD can display resistance changes in real time, and can be modified to measure resistance of ventilated patients and made as portable as a camera. We have used APD it its current implementation to measure average respiratory resistance, as well as separate inspiratory and expiratory values, in nearly 1,500 people. The Phase I clinical data shows that the Standard Deviation (SD) for APD is smaller than IOS on identical measurements. Existing competitive commercial Pulmonary Function Testing (PFT) devices include spirometry, forced oscillation (FO, e.g. IOS), and interrupter (Rint). These either require patients to forcefully exhale (spirometers), or are very expensive and very sensitive to airflow leak (forced oscillation, FO, such as IOS), or require complete interruption of airflow limiting data acquired to only one measurement every 3 breaths (Rint). Three major advantages of APD include a requirement for natural breathing only, relatively less effect from airflow leak than in FO, and it provides an order of magnitude more measurements than Rint. APD can be used by young children, ill adults and in elderly patients. Phase I funding enabled us to considerably advance APD to its current configuration. Pre-Phase I APD weight/cost were 10 pounds/$3,500. APD is now 14.7 ounces/$600, and portable. In Phase II we plan to further reduce its size and cost, improve the flow sensor's accuracy and sensitivity, and add additional capabilities including flow-volume display. To bring APD into commercial production (our long term objective), further refinements are necessary. After that, clinical data must be obtained, and regulatory approval must be sought. The market for the APD is huge, including hospitals, clinics, physician's offices, ambulances, and home care facilities. Because of its size and cost and ease of operation, the APD is an ideal device for home use and for pharmaceutical testing of new drugs. In Phase II we plan to test the device on at least 1,750 individuals at 4 different clinics. Chronic obstructive pulmonary disease (COPD) is fourth leading cause of death in the United States; and respiratory screening for Asthma and COPD, and monitoring of therapeutic interventions are important in US health care. Because of its small size, modest cost, ease of operation and sensitivity to small airway function, the proposed device (APD) can effectively and economically screen for respiratory disease, and monitor interventions in patients with COPD and other respiratory disorders. This will improve diagnosis and recognition of therapeutic benefits as well as lower the cost of the health care.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Research funding history

5 SBIR/STTR records share this UEI (1983–2010). Reported award amounts total $1,294,065. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Health and Human Services, Department of Defense

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.