SBIR/STTR Research Award

An intramedullary device for less invasive surgical fixation of wrist fractures

Award identifier 663fb9142d3288c88bb63220abcc769fd5349a9f5c709cf1417999158c817e6bAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$137,639

Program and phase

SBIR · Phase I

Award year

2011

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
ENDOORTHOPAEDICS, INC.
Proposal award date
Not reported
Contract end date
Not reported
UEI
Not reported
Solicitation number
PA10-050
Topic code
NIAMS

Research abstract

DESCRIPTION (provided by applicant): The distal radius is one of the most common sites of bone fracture and is the most common fracture site in the upper extremity, accounting for approximately 10% of all fractures in adults. Approximately 25% of patients(~80,000/year) require surgery to correctly repair this bone, and current practice requires the surgeon to disrupt the soft tissues surrounding the joint to expose the bone for placement of hardware to stabilize the fracture. Thus, improved joint stabilityis achieved by sacrificing the integrity of an extensive tendon, ligament and neuromuscular network that is needed for proper wrist function. EndoOrthopaedic's core technology is a universal system of telescopic, micro-adjustable bone implants (TABI) forintramedullary fixation that can be assembled by the surgeon entirely within a fracture to restore the shape of the articulating surfaces. Adaptation of our TABI device for intramedullary fracture fixation of the distal radius would provide orthopaedic surgeons with a valuable option in the treatment of distal radial fractures. The device is designed to be deployed during a minimally invasive surgery, thereby reducing the cost of each surgery and minimizing the risk associated with soft tissue damage duringthe procedure. Also, since the device is completely intramedullary, it will not interfere with the soft tissues after the fracture has healed, which will substantially reduce the need for revision surgeries. For these reasons, the TABI device will lead toan overall reduction in the costs associated with treatment of distal radial fractures. Despite the advantages of intramedullary fixation, there has been limited evidence demonstrating the ability of an intramedullary device to sufficiently resist interfragmentary strains in distal radial fractures during habitual loading. The device must also have sufficient strength to prevent re-fracture during periodic overloading. In order to meet these requirements, the TABI device has been designed using proprietarymethods of stabilizing distal radius fractures to minimize the relative motion between fragments. Therefore, our hypothesis is that intramedullary fixation of the distal radial metaphysis using the TABI device will sufficiently stabilize the fracture forrepair. We will test this hypothesis with the following aims: (1) evaluate the ability of the EndoOrthopaedics device (TABI) to resist periodic overloading, and (2) to verify the ability of the TABI device to sufficiently stabilize the fracture and maintain interfragmentary strains below the threshold for fracture healing under sustained habitual mechanical loading. These experiments will determine the feasibility of the TABI device for distal radial fractures, and in Phase 2, we will perform in situ testing of the device to predict its biological effect on fracture healing. PUBLIC HEALTH RELEVANCE: Relevance The distal radius is one of the most common sites of bone fracture and is the most common fracture site in the upper extremity. Approximately 25% of patients (~80,000/year) require surgery to correctly repair this bone, although current treatments for this type of fracture require substantial disruption the soft tissues surrounding the joint. EndoOrthopaedic's core fracture fixation technology (TABI) can be assembled by the surgeon entirely within the fracture during a minimally invasive procedure, which will limit patient discomfort and minimize soft tissue damage. The overall objective of this study is to determine the feasibility of using our TABI device to repair a distal radial fracture.

Technology keywords

Not reported

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.