SBIR/STTR Research Award

Simultaneous fetal echocardiography and magnetocardiography

Award identifier 676c8ac15bbdd18d84d7b81684ec6a9697f6b84dfd61e6ebc4bbf03f4d4dd74eAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$749,822

Program and phase

SBIR · Phase II

Award year

2008

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
TRISTAN TECHNOLOGIES, INC.
Proposal award date
Not reported
Contract end date
Not reported
UEI
Z2E6MXZKNGK9
Solicitation number
PHS2007-2
Topic code
Not reported

Research abstract

DESCRIPTION (provided by applicant): Electrophysiological and mechanical interactions in the fetus are largely unstudied. There is an established need to enhance the current echocardiography/Doppler capabilities of recognizing the fetus at risk of life th reatening cardiac complications. Direct simultaneous comparison of fetal magnetocardiography using Superconducting Quantum Interference Device (SQUID) magnetometry and Doppler will allow, for the first time, assessment of electromechanical disturbances ass ociated with heart failure and severe arrhythmia. This instrument will directly address the fetal cardiac disorders that effect about 1-3% of all pregnancies. This proposal aims to develop an fMCG vector gradiometer instrument specifically designed for com bined use with echocardiography for the characterization of the intrauterine clinical condition of fetuses with life- threatening arrhythmias, acquired heart failure, and structural congenital heart disease. The system will have in addition a very small ta il and radial gap so the echo probe can be positioned very closely over the same area. Compared to existing conventional one-component magnetometers, the instrument will be inexpensive, lightweight and easily producible. The system can be either a stand-al one or an add-on to existing MEG rooms. Neither of the existing MEG or MCG systems are designed for these types of measurements. In addition the system will make the use of at least one type of Echocardiac transducer reliable when positioned 2 cm from the base of the system. This probe will be capable of being rigid adjacent to the system or adjustable in rotation and tilt remotely as desired. Several key technical issues were identified, which will be addressed in Phase II. Vector coils are needed to ensur e that the (arbitrarily positioned) fetal heart can be detected with reasonable signal strength. There is a need to stabilize the transducer, while permitting the required degree of maneuverability for ultrasound imaging. Third is the need to reduce the si ze of the fMCG sensor array in order to provide greater access to the maternal surface for echo/Doppler imaging. Fourth is the development of optimal signal processing techniques for the new sensor configuration, particularly for reduction of non-stationar y low frequency interference. And fifth is the need to better study the relationship between the echo/Doppler transducer positioning (angle and orientation) and the sensor array positioning, in order to facilitate the recording of additional or more tradit ional Doppler planes while not compromising, and perhaps even facilitating the quality of the fMCG signal. The findings on Phase I generated enough knowledge to develop, and assured the need of a suitable instrument capable of simultaneous ultrasound/fMCG recordings. The successful completion of this program has the potential to lead to a significant ability to identify fetal arrhythmias. In addition, this product should enhance assessment of fetal well-being by identifying risk factors for sudden fetal dea th, including cardiac ischemia, QT prolongation, and electromechanical dysfunction. This proposal aims to develop better methods of characterizing the intrauterine clinical condition of fetuses with life-threatening arrhythmias, acquired heart failure, and structural congenital heart disease by the development of an economical, noninvasive simultaneous fetal echocardiography and magnetocardiography system. Direct simultaneous comparison of fetal magnetocardiographic (fMCG) recordings in conjunction with Echocardiography and Doppler (echo/Doppler), will enhance current echo/Doppler capabilities of recognizing the fetus at risk of life-threatening cardiac complications. We are developing the first instrument specially designed for these dual measurements.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Research funding history

32 SBIR/STTR records share this UEI (1989–2021). Reported award amounts total $12,834,417. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Health and Human Services, Department of Defense

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.