SBIR/STTR Research Award

Noninvasive Raman Monitoring of Urea During Hemodialysis

Award identifier 5b10277c153b27ce8c6506f80687eaa9df06fa9b796675699899ed3252d33251Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$703,525

Program and phase

SBIR · Phase II

Award year

2003

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
RAMAN SYSTEMS, INC.
Proposal award date
Not reported
Contract end date
Not reported
UEI
Not reported
Solicitation number
Not reported
Topic code
Not reported

Research abstract

DESCRIPTION (provided by applicant): It is the aim of the present Phase II research program to develop a continuous, noninvasive, on-line process for optically monitoring the levels of urea in a patient's blood during hemodialysis. The ultimate goal of such a process is to provide a direct and continuous measure of the efficiency of dialysis without having to wait for the drawing of a blood sample, thereby providing an assessment of whether dialysis at any point in time has reached an effective stopping point for the patient while still attached to the dialysis equipment. We propose to utilize low-resolution laser Raman scattering for the direct measurement of the urea levels in blood using the optical access provided by the dialysis tubing delivering the patient's blood to the dialyzer. Our Phase I SBIR results have shown that urea has a unique Raman spectroscopic signature in animal blood and can be identified and quantified against a whole blood background. Our Phase II program is designed to assess the capability of Raman to quantify the levels of urea in human blood samples with varying concentrations of urea present. After constructing a suitable multiple regression model for BUN, we will build out an appropriate low-resolution Raman module for attachment to a hemodialysis unit and expand the investigation to human blood analysis for BUN and URR during actual dialysis procedures in the clinical setting. If successful, a Raman measurement approach would allow, for the first time, real-time, direct and continuous monitoring of the progress of urea removal dudng the course of hemodialysis. This would permit more efficient timing of the dialysis procedure for the patient, as well as providing an ongoing readout of the effectiveness of the dialysis system during patient treatment. We anticipate that a commercially viable urea monitor might be produced rapidly, if the Phase II work is successful, by the adaptation for the clinical setting of the Company's present R-2001 Raman module for attachment by fiberoptic probe to existing renal dialysis equipment.

Technology keywords

Not reported

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.