SBIR/STTR Research Award

An implantable intraocular pressure control system

Award identifier c9e073782d34c6a1326061104dbbbf349609b1107fdcce9ce806908467238a20Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$99,231

Program and phase

SBIR · Phase I

Award year

2007

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
FORSYTHE TECHNOLOGIES WORLDWIDE, INC.
Proposal award date
Not reported
Contract end date
Not reported
UEI
Not reported
Solicitation number
Not reported
Topic code
Not reported

Research abstract

DESCRIPTION (provided by applicant): Glaucoma, a widespread, chronic disease, is a leading cause of blindness. In the most prevalent form of glaucoma, primary open-angle glaucoma (POAG), increased intraocular pressure (IOP) is the most common risk factor. Results from large clinical trials indicate that decreasing IOP in glaucoma patients delays the development of vision loss (Palmberg, 2002). Even glaucoma patients with IOPs in the normal range benefit from decreasing their IOP. Currently, numerous pharmacological and surgical approaches are employed to reduce IOP in glaucoma patients. However, drug treated patients are frequently non- compliant, refractory and/or suffer from adverse effects. Current surgical implants are passive devices unable to detect or respond to changes in IOP and frequently fail. With either approach, a patient office visit is required for the physician to manually verify IOP control by tonometry. We propose to create an implant capable of both sensing IOP and regulating it through opening and closing a miniature valve. The implant's power supply will be self- contained, with a transceiver capable of sending and receiving external commands. In its final form the implant will monitor and regulate IOP and be capable of sending IOP data and information concerning valve function to the physician and/or patient. A data collection system will also be constructed to record and document all parameters on a PC. In this Phase I feasibility study we will construct a working prototype of the valve and conduct in vitro and in vivo tests. The three specific, measurable objectives for Phase I are to: Design and fabricate a miniature twin magnetic stop/electromagnetic valve with accompanying telemetry and data acquisition system. Perform short and long-term in vitro tests of the valve to demonstrate detection, response and control of IOP in the normal and pathological pressure ranges. Implant the valve and test it both acutely and chronically on conscious, active normal IOP rabbits to determine safety and efficacy. Glaucoma, a wide spread ocular disease increases the pressure inside the eye and if left untreated causes blindness. We will create an electronically controlled valve and pressure recorder to be placed in the eye that will reduce this pressure and preserve sight.

Technology keywords

Not reported

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.