SBIR/STTR Research Award

NIH SBIR Phase I: Development of a Novel Boron-doped Ultrananocrystalline Diamond

Award identifier 7e13fe8c45f5d7cba225196af42500cf5b1446d5222cfa5b2860dc33a1389f51Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$148,086

Program and phase

SBIR · Phase I

Award year

2011

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
Advanced Diamond TechNologies, Inc.
Proposal award date
Not reported
Contract end date
Not reported
UEI
JTT9ARG8ZHU5
Solicitation number
PA10-050
Topic code
NIMH

Research abstract

DESCRIPTION (provided by applicant): There is an enormous need for the development of a new class of chemical microsensors that are versatile, selective, sensitive and reliable to allow investigation of the neurobiological mechanisms of behavior and disease symptoms. Currently, the preferred method for monitoring neurotransmitters in vivo real time is fast- scan cyclic voltammetry (FSCV) and the preferred microelectrode material is carbon fiber. We propose here the next generation electrode material, boron-doped ultrananocrystalline diamond (BD UNCD) that offers superior sensitivity and specificity, fast response time, low background currents, long-term stability and resistance to fouling compared to carbon fibers. The goal is to develop a chronically implantable UNCD microsensor for long-term (i.e., months to years) neurochemical recording, especially if human compatible. The specific aims of this project are, (i) to develop a reliable UNCD film deposition process on a tantalum (Ta) wire substrate that is scalable and mass-producible, (ii) to demonstrate microelectrode electrochemical behavior (i.e. higher signal-to-noise ratio) of a patterned UNCD-Ta microsensor using cyclic voltammetry and potassium ferrocyanide solution and (iii) to demonstrate the uniqueadvantages of UNCD microelectrodes by measuring dopamine with flow injection analysis and in the anesthetized rat brain. Some of the planned improvements include modifications to the Ta surface preparation process to increase film adhesion and selective patterning of insulators to produce windows of BD UNCD that should allow consistent microelectrode behavior. As a proof-of-concept, the electrodes will be used to measure dopamine (the most widely studied neurotransmitter) down to 10 nM physiological concentration. The proposed sensor could potentially be used for simultaneous measurement of dopamine and many other important neurotransmitters. If this project is successful, it will readily accomplish many NIH mission goals for the Division of Neuroscience and Basic Behavioral Science, specifically: 1) for in vivo voltammetry - the UNCD is bioinert and highly selective due to its surface chemistry and small pseudo capacitance; 2) for biocompatible biomaterials - UNCD/parylene passivation is novel and completely biocompatible for chronic neurochemical sensing; 3) for nanotechnologies' - application of UCND and nanometer thick insulators greatly advance the way in which probes are fabricated; and 4) for biosensors - UNCD can be easily modified with antibodies and oligonucleotide probes through photochemical or electrochemical means. A recent report suggests that the medical sensing market will reach 10.9 billion in 2012. If only 0.1% ( 10.9 million) of that market is accessible by UNCD microelectrode technology, it would still be sufficient justification for the proposed work. Also, a greater understanding of real-time sensing of neurotransmitters from this project would enable alternative applications for the technology, including: low-cost, point-of-use,portable, implantable sensors for toxins, metabolites and disease biomarkers. PUBLIC HEALTH RELEVANCE: This project will develop a microsensor technology using Ultrananocrystalline diamond electrodes to further advance the neuroscience field (brain function and disease symptoms). Its versatility, sensitivity and reliability are ideally suited for real-time, chronic measurement of multiple neurochemicals and brain activity mapping.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

25 SBIR/STTR records share this UEI (2004–2017). Reported award amounts total $6,246,720. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: National Science Foundation, Department of Health and Human Services, Department of Energy, Environmental Protection Agency, Department of Defense

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.