SBIR/STTR Research Award
Anti-fibrotic Coatings for Rapidly Exchangeable Bioprosthetic Heart Valve
Award amount
$1,616,040Program and phase
SBIR · Phase IIAward year
2008Award details
- Awarding agency
- Department of Health and Human Services
- Branch
- National Institutes of Health
- Recipient company
- VALVEXCHANGE, INC.
- Proposal award date
- Not reported
- Contract end date
- Not reported
- UEI
- Not reported
- Solicitation number
- PHS2007-2
- Topic code
- Not reported
Research abstract
DESCRIPTION (provided by applicant): Each year, over 100,000 patients in the United States need to have their diseased heart valves replaced with artificial devices. Although bioprostheses, valves made from animal tissues, are considered ideal for most pat
ients, they wear out in about 15 years. They are thus used primarily in the elderly patient who is not expected to outlive the valve. Younger patients receive mechanical valves that are more durable, but require chronic administration of blood thinners. Th
is makes participation in most sports impossible and exposes the patient to increased risk for fatal bleeds and strokes. ValveXchange, Inc. ( VXI ) is a medical device company developing a two-part heart valve consisting of a surgically implanted base and
an exchangeable bioprosthetic tissue leaflet set. The VXI device is a lifetime tissue valve replacement system that does not require anticoagulation. During the first surgery, the docking station is first sewn in place and the leaflets are snapped in. This
allows the surgeon to place sutures more conveniently, without risk of damaging the leaflet core. As the leaflet set begins to show signs of wear it can be exchanged rapidly, using a minimally invasive surgical or percutaneous procedure. Rapid, minimally
invasive leaflet exchange dramatically reduces surgical time and eliminates the need the technically demanding and potentially dangerous re-excision of the initial prosthetic valve. As the leaflet set is exchanged, the docking station remains permanently i
n place so there is no disruption of the sensitive tissue of the aortic root; a vital part of the conduction system of the heart and the origin of the coronary arteries. VXI has successfully completed two Phase I projects. In the first, VXI develop
ed prototype exchangeable valves and demonstrated their technical feasibility in an animal model by exchanging a valve in 23 seconds. In the second, VXI investigated the ability of anti-adhesion coatings to abate fibrotic overgrowth in the hyper-fibrotic s
heep model. In this Phase II application we propose to implement our novel anti-adhesion coatings in a chronic sheep model and investigate the long-term host response of the rapidly exchangeable valve. We will fabricate 8 valves each from bare coba
lt-chrome, cobalt-chrome treated with a stearate coating, and from pyrolitic carbon. Both stearate and pyrolitic carbon have been shown to repel fibrotic overgrowth in the Phase I study. A control group will make use of the gold standard Edwards pericard
ial valve. After 3 and 5 months of implantation, the leaflet sets will be exchanged using an open surgical procedure in which the reduced time on cardiac bypass will be documented, and the degree of fibrotic overgrowth measured. Detailed measurements of fi
brotic overgrowth and incidence of thromboembolism will be examined at necropsy. This revised resubmission now includes more specific criteria upon which to base a redesign of the valve and the anti-fibrotic coatings. Each year, over 100,000 patients in th
e United States need to have their diseased heart valves replaced with artificial devices. Although artificial heart valves made from materials of animal origin are considered ideal for most patients, they wear out in about 15 years. They are thus used pri
marily in the elderly patient who is not expected to outlive the valve. Younger patients receive mechanical valves, made from metals and graphite-like materials. Although these types of valves will last the life of the patient, they require the patient to
be on blood thinners. This makes participation in most sports impossible and exposes the patient to increased risk for fatal bleeds and strokes. ValveXchange, Inc. ( VXI ) is a medical device company developing a two-part heart valve consisting of a surgic
ally implanted base and an exchangeable animal tissue-based leaflet set. The VXI device is a lifetime tissue valve replacement system that does not require
Technology keywords