SBIR/STTR Research Award

Anti-fibrotic Coatings for Rapidly Exchangeable Bioprosthetic Heart Valve

Award identifier d0388ef4a22064784f6bc3649cccc36f8be5bebd578ab7183f511ceb3708a2cfAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$1,616,040

Program and phase

SBIR · Phase II

Award year

2008

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
VALVEXCHANGE, INC.
Proposal award date
Not reported
Contract end date
Not reported
UEI
Not reported
Solicitation number
PHS2007-2
Topic code
Not reported

Research abstract

DESCRIPTION (provided by applicant): Each year, over 100,000 patients in the United States need to have their diseased heart valves replaced with artificial devices. Although bioprostheses, valves made from animal tissues, are considered ideal for most pat ients, they wear out in about 15 years. They are thus used primarily in the elderly patient who is not expected to outlive the valve. Younger patients receive mechanical valves that are more durable, but require chronic administration of blood thinners. Th is makes participation in most sports impossible and exposes the patient to increased risk for fatal bleeds and strokes. ValveXchange, Inc. ( VXI ) is a medical device company developing a two-part heart valve consisting of a surgically implanted base and an exchangeable bioprosthetic tissue leaflet set. The VXI device is a lifetime tissue valve replacement system that does not require anticoagulation. During the first surgery, the docking station is first sewn in place and the leaflets are snapped in. This allows the surgeon to place sutures more conveniently, without risk of damaging the leaflet core. As the leaflet set begins to show signs of wear it can be exchanged rapidly, using a minimally invasive surgical or percutaneous procedure. Rapid, minimally invasive leaflet exchange dramatically reduces surgical time and eliminates the need the technically demanding and potentially dangerous re-excision of the initial prosthetic valve. As the leaflet set is exchanged, the docking station remains permanently i n place so there is no disruption of the sensitive tissue of the aortic root; a vital part of the conduction system of the heart and the origin of the coronary arteries. VXI has successfully completed two Phase I projects. In the first, VXI develop ed prototype exchangeable valves and demonstrated their technical feasibility in an animal model by exchanging a valve in 23 seconds. In the second, VXI investigated the ability of anti-adhesion coatings to abate fibrotic overgrowth in the hyper-fibrotic s heep model. In this Phase II application we propose to implement our novel anti-adhesion coatings in a chronic sheep model and investigate the long-term host response of the rapidly exchangeable valve. We will fabricate 8 valves each from bare coba lt-chrome, cobalt-chrome treated with a stearate coating, and from pyrolitic carbon. Both stearate and pyrolitic carbon have been shown to repel fibrotic overgrowth in the Phase I study. A control group will make use of the gold standard Edwards pericard ial valve. After 3 and 5 months of implantation, the leaflet sets will be exchanged using an open surgical procedure in which the reduced time on cardiac bypass will be documented, and the degree of fibrotic overgrowth measured. Detailed measurements of fi brotic overgrowth and incidence of thromboembolism will be examined at necropsy. This revised resubmission now includes more specific criteria upon which to base a redesign of the valve and the anti-fibrotic coatings. Each year, over 100,000 patients in th e United States need to have their diseased heart valves replaced with artificial devices. Although artificial heart valves made from materials of animal origin are considered ideal for most patients, they wear out in about 15 years. They are thus used pri marily in the elderly patient who is not expected to outlive the valve. Younger patients receive mechanical valves, made from metals and graphite-like materials. Although these types of valves will last the life of the patient, they require the patient to be on blood thinners. This makes participation in most sports impossible and exposes the patient to increased risk for fatal bleeds and strokes. ValveXchange, Inc. ( VXI ) is a medical device company developing a two-part heart valve consisting of a surgic ally implanted base and an exchangeable animal tissue-based leaflet set. The VXI device is a lifetime tissue valve replacement system that does not require

Technology keywords

Not reported

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.